4.1.14 12-** Ethernet
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
12-0* IP Settings
12-00 IP Address Assignment
null
2 set-ups
TRUE
-
Uint8
12-01 IP Address
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-02 Subnet Mask
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-03 Default Gateway
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-04 DHCP Server
0 N/A
2 set-ups
TRUE
0
OctStr[4]
12-05 Lease Expires
App.Dependent
All set-ups
TRUE
0
TimD
12-06 Name Servers
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-07 Domain Name
0 N/A
1 set-up
TRUE
0
VisStr[48]
12-08 Host Name
0 N/A
1 set-up
TRUE
0
VisStr[48]
12-09 Physical Address
0 N/A
1 set-up
TRUE
0
VisStr[17]
12-1* Ethernet Link Parameters
12-10 Link Status
[0] No Link
1 set-up
TRUE
-
Uint8
12-11 Link Duration
App.Dependent
All set-ups
TRUE
0
TimD
12-12 Auto Negotiation
[1] On
2 set-ups
TRUE
-
Uint8
12-13 Link Speed
[0] None
2 set-ups
TRUE
-
Uint8
12-14 Link Duplex
[1] Full Duplex
2 set-ups
TRUE
-
Uint8
12-2* Process Data
12-20 Control Instance
App.Dependent
1 set-up
TRUE
0
Uint8
12-21 Process Data Config Write
App.Dependent
All set-ups
TRUE
-
Uint16
12-22 Process Data Config Read
App.Dependent
All set-ups
TRUE
-
Uint16
12-23 Process Data Config Write Size
16 N/A
All set-ups
TRUE
0
Uint32
12-24 Process Data Config Read Size
16 N/A
All set-ups
TRUE
0
Uint32
12-27 Primary Master
0 N/A
1 set-up
FALSE
0
12-28 Store Data Values
[0] Off
All set-ups
TRUE
-
Uint8
12-29 Store Always
[0] Off
1 set-up
TRUE
-
Uint8
12-3* EtherNet/IP
12-30 Warning Parameter
0 N/A
All set-ups
TRUE
0
Uint16
12-31 Net Reference
[0] Off
2 set-ups
TRUE
-
Uint8
12-32 Net Control
[0] Off
2 set-ups
TRUE
-
Uint8
12-33 CIP Revision
App.Dependent
All set-ups
TRUE
0
Uint16
12-34 CIP Product Code
App.Dependent
1 set-up
TRUE
0
Uint16
12-35 EDS Parameter
0 N/A
All set-ups
TRUE
0
Uint32
12-37 COS Inhibit Timer
0 N/A
All set-ups
TRUE
0
Uint16
12-38 COS Filter
0 N/A
All set-ups
TRUE
0
Uint16
12-4* Modbus TCP
12-40 Status Parameter
0 N/A
All set-ups
TRUE
0
Uint16
12-41 Slave Message Count
0 N/A
All set-ups
TRUE
0
Uint32
12-42 Slave Exception Message Count
0 N/A
All set-ups
TRUE
0
Uint32
12-5* EtherCAT
12-50 Configured Station Alias
0 N/A
1 set-up
FALSE
0
Uint16
12-51 Configured Station Address
0 N/A
All set-ups
TRUE
0
Uint16
12-59 EtherCAT Status
0 N/A
All set-ups
TRUE
0
Uint32
Table 4.17
Parameter Lists
VLT
®
AutomationDrive Programmming Guide
MG33ME02 - VLT
®
is a registered Danfoss trademark
177
4
4
Содержание VLT AutomationDrive FC 300 Series
Страница 1: ...MAKING MODERN LIVING POSSIBLE Programming Guide VLT AutomationDrive...
Страница 210: ...www danfoss com drives MG33ME02 130R0334 MG33ME02 Rev 2012 02 20...
Страница 211: ......