6-70 Terminal X45/1 Output
Option:
Function:
[135] Torque%
nom 4-20
mA
The torque setting is related to the motor
torque setting.
[136] Power 4-20
mA
Taken from
[137] Speed 4-20
mA
Taken from
. 20 mA
= Value in
.
[138] Torque 4-20
mA
Torque reference related to 160% torque.
[139] Bus ctrl.
0-20 mA
An output value set from fieldbus process
data. The output will work independently of
internal functions in the frequency converter.
[140] Bus ctrl.
4-20 mA
An output value set from fieldbus process
data. The output will work independently of
internal functions in the frequency converter.
[141] Bus ctrl.
0-20 mA,
timeout
defines the
behaviour of the analog output in case of
bus time-out.
[142] Bus ctrl.
4-20 mA,
timeout
defines the
behaviour of the analog output in case of
bus time-out.
[150] Max Out
Freq 4-20
mA
In relation to
.
6-71 Terminal X45/1 Output Min Scale
Range:
Function:
0.00%
*
[0.00 -
200.00%]
Scale the minimum output of the selected
analog signal at terminal X45/1, as a
percentage of the maximum signal value.
E.g. if 0 mA (or 0 Hz) is desired at 25% of
the maximum output value, then
programme 25%. Scaling values up to
100% can never be higher than the
corresponding setting in
6-72 Terminal
X45/1 Max. Scale
.
6-72 Terminal X45/1 Output Max Scale
Range:
Function:
100%
*
[0.00 -
200.00%]
Scale the maximum output of the selected
analog signal at terminal X45/1. Set the value
to the maximum value of the current signal
output. Scale the output to give a current
lower than 20 mA at full scale; or 20 mA at
an output below 100% of the maximum
signal value. If 20 mA is the desired output
current at a value between 0 - 100% of the
full-scale output, programme the percentage
value in the parameter, i.e. 50% = 20 mA. If a
current between 4 and 20 mA is desired at
maximum output (100%), calculate the
percentage value as follows (example where
desired max. output is 10 mA):
6-72 Terminal X45/1 Output Max Scale
Range:
Function:
IRANGE mA
IDESIRED MAX mA
x 100 %
= 20 − 4 mA
10
mA
x 100 % = 160 %
130BA877.10
[mA]
0%
20
0/4
100%
Current
Analogue
output Min
Scale
par. 6-71
Variable for
output
example:Speed
[RPM]
Analogue
Output Max
Scale
par. 6-72
Illustration 3.44
6-73 Terminal X45/1 Output Bus Control
Range:
Function:
0.00%
*
[0.00 - 100.00%] Holds the level of Analog Output 3
(terminal X45/1) if controlled by bus.
6-74 Terminal X45/1 Output Timeout Preset
Range:
Function:
0.00%
*
[0.00 -
100.00%]
Holds the preset level of Analog Output
3 (terminal X45/1).
In case of a bus timeout and a timeout
function is selected in
6-70 Terminal
X45/1 Output
the output will preset to
this level.
3.8.9 6-8* Analog Output 4 MCB 113
Parameters for configuring the scaling and limits for
analog output 4. Terminal X45/3 and X45/4. Analog
outputs are current outputs: 0/4 – 20 mA. Resolution on
analog output is 11 bit.
6-80 Terminal X45/3 Output
Option:
Function:
Select the function of Terminal X45/3 as an
analog current output.
[0]
*
No operation Same selections available as for
6-70 Terminal
X45/1 Output
Parameter Descriptions
VLT
®
AutomationDrive Programmming Guide
MG33ME02 - VLT
®
is a registered Danfoss trademark
97
3
3
Содержание VLT AutomationDrive FC 300 Series
Страница 1: ...MAKING MODERN LIVING POSSIBLE Programming Guide VLT AutomationDrive...
Страница 210: ...www danfoss com drives MG33ME02 130R0334 MG33ME02 Rev 2012 02 20...
Страница 211: ......