background image

V

isit us on the web:

www.servo-repair.com 

www.servorepair.ca

www.ferrocontrol.com 

www.sandvikrepair.com

www.accuelectric.com

For 24/7 repair services : 

USA: 1 (888) 932 - 9183 
Canada: 1 (905) 829 -2505 

Emergency After hours: 1 (416) 624 0386 

Servicing USA and Canada

Scroll down to view your document!

Over 

1

0

0 years cumulative experience 

24 hour rush turnaround / t

echnical support service 

Established in 1993 

T

he leading independent repairer of servo motors and drives in 

N

orth America.

Summary of Contents for Superior SLO-SYN SS2000MD4-M

Page 1: ...pair services USA 1 888 932 9183 Canada 1 905 829 2505 Emergency After hours 1 416 624 0386 Servicing USA and Canada Scroll down to view your document Over 100 years cumulative experience 24 hour rush...

Page 2: ...www DanaherMotion com Installation Instructions for SLO SYN MODEL SS2000MD4 M Microstep Translator Drive 400030 060 Rev H...

Page 3: ...________ 12 4 3 ENVIRONMENTAL SPECIFICATIONS_____________________________ 12 4 4 MOTOR COMPATIBILITY _______________________________________ 12 4 5 CURRENT SETTINGS____________________________________...

Page 4: ...m date of shipment from the Company s factory or a warehouse of the Company in the event that the equipment is purchased from the Company or for a period of one year from the date of shipment from the...

Page 5: ...y equipment or parts thereof must be obtained from the Company The Company shall not be responsible for any transportation charges IF FOR ANY REASON ANY OF THE FOREGOING PROVISIONS SHALL BE INEFFECTIV...

Page 6: ...tepper Motors are given in Section 5 Section 6 Troubleshooting outlines procedures to follow if the Translator Drive fails to operate properly Appendix A provides procedures for troubleshooting electr...

Page 7: ...Section 4 4 for a list of compatible motors 2 Set the correct current level for the motor being used per the instruc tions in Section 4 5 Heat sinking may be required to maintain case temperature bel...

Page 8: ...oating of thermal compound between the drive and the mounting surface before fastening the unit in place Do not use too much thermal compound It is better to use too little than too much Figure 3 1 Mo...

Page 9: ...t and its wiring from electrical noise sources If this cannot be done keep the drive at least three feet 0 9 m from any noise sources 3 2 TERMINAL LOCATIONS AND ASSIGNMENTS Figure 3 2 shows the termin...

Page 10: ...he motor frame must be grounded Cabling from the drive to the motor should be done with a shielded twisted pair cable The wires for each motor phase should be twisted together about six times per foot...

Page 11: ...6 2 7 8 DRIVE PIN 1 DRIVE PIN 2 DRIVE PIN 1 DRIVE PIN 2 DRIVE PIN 1 DRIVE PIN 2 DRIVE PIN 4 DRIVE PIN 3 DRIVE PIN 4 DRIVE PIN 3 DRIVE PIN 4 DRIVE PIN 3 D F B H 5 4 1 3 WHITE RED RED 8 LEAD MOTORS PARA...

Page 12: ...d voltage parameters It is recommended that the power supply leads be twisted together using approximately six twists per foot 0 3 m If the power supply is grounded it must only be grounded on the neg...

Page 13: ...may be required Storage 40 F to 167 F 40 C to 75 C Humidity 95 max noncondensing Altitude 10 000 feet 3048 m max 4 4 MOTOR COMPATIBILITY Motor Types Superior Slo Syn M and KM Series M Series Frame Siz...

Page 14: ...FO8 3 5 1 0 2 0 KML060F11 3 5 1 0 2 0 KML061FO5 2 5 1 2 1 5 KML061F11 3 5 1 0 3 0 KML062F07 3 0 1 0 2 5 KML062F13 3 5 1 0 4 0 KML063F07 3 0 1 5 2 0 KML063F13 3 5 1 0 4 0 KML091F07 3 0 1 0 2 0 KML091F1...

Page 15: ...Current amperes None 1 0 1 1 5 2 2 0 3 2 5 4 3 0 5 3 5 4 6 AUTOMATIC CURRENT REDUCTION When switch 6 is in the OFF position the current at standstill goes to 50 of the selected level This occurs betw...

Page 16: ...UTION SWITCHES Figure 4 1 Switches For Setting Current Level And Step Resolution 4 8 SIGNAL SPECIFICATIONS 4 8 1 Terminal Assignments All connections are made via the 4 pin terminal strip J1 Pin Assig...

Page 17: ...tor from the end opposite the mounting flange AWO All Windings Off Input When this signal is low AC and DC current to the motor is zero There is no holding torque when the AWO signal is low If you are...

Page 18: ...e Figure 4 2 4 9 INDICATOR LIGHTS FAULT LED Red Lights to indicate over current condition This condition is caused by mo tor wiring errors or a ground fault Recovery from over current condition requir...

Page 19: ...celeration deceleration through the resonance areas aid in reducing instability to a level that provides smooth shaft velocity and accurate positioning If instability does cause unacceptable performan...

Page 20: ...URVES The test conditions used when obtaining the torque versus speed data are listed in the lower left hand corner of each curve 1 10 MICROSTEP M061LE08 ETC MOTORS SERIES CONNECTED 1 10 MICROSTEP M06...

Page 21: ...20 1 10 MICROSTEP M062LE09 ETC MOTORS SERIES CONNECTED 1 10 MICROSTEP M062LE09 ETC MOTORS PARALLEL CONNECTED...

Page 22: ...21 1 10 MICROSTEP M063LE09 ETC MOTORS SERIES CONNECTED 1 10 MICROSTEP M063LE09 ETC MOTORS PARALLEL CONNECTED...

Page 23: ...22 1 10 MICROSTEP M091 FD8109 ETC MOTORS SERIES CONNECTED 1 10 MICROSTEP M091 FD8109 ETC MOTORS PARALLEL CONNECTED...

Page 24: ...23 1 10 MICROSTEP M092 FD8109 ETC MOTORS SERIES CONNECTED 1 10 MICROSTEP M092 FD8109 ETC MOTORS PARALLEL CONNECTED...

Page 25: ...24...

Page 26: ...25...

Page 27: ...26...

Page 28: ...27...

Page 29: ...at the motor is a correct model for use with this unit Specifically IF MOTOR DIRECTION IS REVERSED Check For Reversed connections to the Motor Connector Reversing the phase A or the phase B connection...

Page 30: ...ms exist use appropriate line conditioning such as line filters or isolation transformers 2 Follow proper wiring practices for location grounding wiring and relay suppression 3 Double check the ground...

Page 31: ...conveniently located to provide prompt attention to customers needs Call the nearest office listed for ordering and application information or for the address of the closest authorized distributor IN...

Reviews: