5.1.3 Active/Inactive Parameters in Different Drive Control Modes
+
indicates that the parameter is active in the mode.
-
indicates that the parameter is inactive in the mode.
Parameter 1-10 Motor Construction
AC motor
Parameter 1-01 Motor Control Principle
U/f mode
VVC
+
Parameter 1-00 Configuration Mode
[0] Speed Open Loop
+
+
[1] Speed Closed Loop
-
+
[3] Process
+
+
[4] Torque Open Loop
-
+
[6] Surface Winder
+
+
[7] Ext. PID Open Loop
+
+
Parameter 1-03 Torque Characteristics
-
+ see
1, 2, 3)
Parameter 1-06 Clockwise Direction
+
+
Parameter 1-20 Motor Power [kW]
(
parameter 0-03 Regional Settings
=
[0] International
)
+
+
Parameter 1-22 Motor Voltage
+
+
Parameter 1-23 Motor Frequency
+
+
Parameter 1-24 Motor Current
+
+
Parameter 1-25 Motor Nominal Speed
+
+
Parameter 1-29 Automatic Motor Adaptation (AMA)
+
+
Parameter 1-30 Stator Resistance (Rs)
+
+
Parameter 1-33 Stator Leakage Reactance (X1)
+
+
Parameter 1-34 Rotor Leakage Reactance (X2)
-
+ see
5)
Parameter 1-35 Main Reactance (Xh)
+
+
Parameter 1-39 Motor Poles
+
+
Table 5.3 Active/Inactive Parameters
1) Constant torque
2) Variable torque
3) AEO
5) Used in flystart
Parameter 1-10 Motor Construction
AC motor
Parameter 1-01 Motor Control Principle
U/f mode
VVC
+
Parameter 1-50 Motor Magnetisation at Zero Speed
-
+
Parameter 1-52 Min Speed Normal Magnetising [Hz]
-
+
Parameter 1-55 U/f Characteristic - U
+
-
Parameter 1-56 U/f Characteristic - F
+
-
Parameter 1-60 Low Speed Load Compensation
-
+
Parameter 1-61 High Speed Load Compensation
-
+
Parameter 1-62 Slip Compensation
-
+
see
7)
Parameter 1-63 Slip Compensation Time Constant
+
see
8)
+
Parameter 1-64 Resonance Damping
+
+
Parameter 1-65 Resonance Damping Time Constant
+
+
Parameter 1-71 Start Delay
+
+
Parameter 1-72 Start Function
+
+
Parameter 1-73 Flying Start
-
+
Parameter 1-75 Start Speed [Hz]
-
+
Parameter Lists
VLT
®
AutomationDrive FC 360
122