9-16 PCD Read Configuration
Select the parameters to be assigned to PCD 3–10 of the
telegrams. The number of available PCDs depends on the
telegram type. Values in PCD 3 to 10 contain the actual data
values of the selected parameters.
Option:
Function:
[1663]
Terminal 54 Setting
[1664]
Analog Input AI54
[1665]
Analog Output 42 [mA]
[1667]
Pulse Input 29[Hz]
[1668]
Pulse Input 33 [Hz]
[1669]
Pulse Output 27 [Hz]
[1670]
Pulse Output 29 [Hz]
[1671]
Relay Output
[1672]
Counter A
[1673]
Counter B
[1679]
Analog Output AO45
[1684]
Comm. Option STW
[1685]
FC Port CTW 1
[1690]
Alarm Word
[1691]
Alarm Word 2
[1692]
Warning Word
[1693]
Warning Word 2
[1694]
Ext. Status Word
[1695]
Ext. Status Word 2
[1697]
Alarm Word 3
[3421]
PCD 1 Read For Application
[3422]
PCD 2 Read For Application
[3423]
PCD 3 Read For Application
[3424]
PCD 4 Read For Application
[3425]
PCD 5 Read For Application
[3426]
PCD 6 Read For Application
[3427]
PCD 7 Read For Application
[3428]
PCD 8 Read For Application
[3429]
PCD 9 Read For Application
[3430]
PCD 10 Read For Application
[3450]
Actual Position
[3456]
Track Error
9-18 Node Address
Range:
Function:
126
*
[ 0 -
126 ]
Enter the station address in this parameter or,
alternatively, in the hardware switch. To adjust the
station address in
,
set the hardware switch to 126 or 127 (that is all
switches set to
on
). Otherwise, this parameter
shows the actual setting of the switch.
9-19 Drive Unit System Number
Range:
Function:
1037
*
[0 - 65535 ]
Manufacturer specific system ID.
9-22 Telegram Selection
Option:
Function:
[1]
Standard telegram
1
Select a standard PROFIBUS
telegram configuration for the
frequency converter as an
alternative to using the freely
configurable telegrams in
parameter 9-15 PCD Write Configu-
ration
and
.
[100]
*
None
[101]
PPO 1
[102]
PPO 2
[103]
PPO 3
[104]
PPO 4
[105]
PPO 5
[106]
PPO 6
[107]
PPO 7
[108]
PPO 8
[200]
Custom telegram 1
9-23 Parameters for Signals
Option:
Function:
[0]
*
[302]
Minimum Reference
[303]
Maximum Reference
[312]
Catch up/slow Down Value
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[412]
Motor Speed Low Limit [Hz]
[414]
Motor Speed High Limit [Hz]
[416]
Torque Limit Motor Mode
[417]
Torque Limit Generator Mode
[553]
Term. 29 High Ref./Feedb. Value
[558]
Term. 33 High Ref./Feedb. Value
[590]
Digital & Relay Bus Control
[593]
Pulse Out 27 Bus Control
[595]
Pulse Out 29 Bus Control
[615]
Terminal 53 High Ref./Feedb. Value
[625]
Terminal 54 High Ref./Feedb. Value
[696]
Terminal 42 Output Bus Control
[748]
PCD Feed Forward
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[1500]
Operating hours
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
[1601]
Reference [Unit]
[1602]
Reference [%]
Parameter Descriptions
Programming Guide
MG06C602