or par. 0-24,
Display Line XXX
. Use the
▲
or
▼
buttons on the LCP to change a character. Use the
◀
and
▶
buttons to move the cursor. When a character is highlighted by the cursor, it can be changed. Use the
▲
or
▼
buttons on the LCP to change a character. A character can be inserted by placing the cursor between two
characters and pressing
▲
or
▼
.
0-38 Display Text 2
Option:
Function:
In this parameter it is possible to write an individual text string for display in the LCP or to be read via serial
communication. If to be displayed permanently select Display Text 2 in par. 0-20, par. 0-21, par. 0-22, par. 0-23
or par. 0-24,
Display Line XXX
. Use the
▲
or
▼
buttons on the LCP to change a character. Use the
◀
and
▶
buttons to move the cursor. When a character is highlighted by the cursor, this character can be changed. A
character can be inserted by placing the cursor between two characters and pressing
▲
or
▼
.
0-39 Display Text 3
Option:
Function:
In this parameter it is possible to write an individual text string for display in the LCP or to be read via serial
communication. If to be displayed permanently select Display Text 3 in par. 0-20, par. 0-21, par. 0-22, par. 0-23
or par. 0-24,
Display Line XXX
. Use the
▲
or
▼
buttons on the LCP to change a character. Use the
◀
and
▶
buttons to move the cursor. When a character is highlighted by the cursor, this character can be changed. A
character can be inserted by placing the cursor between two characters and pressing
▲
or
▼
.
3.2.6. LCP Keypad, 0-4*
Enable, disable and password protect individual keys on the LCP keypad.
0-40 [Hand on] Key on LCP
Option:
Function:
[0]
Disabled
No function
[1]
*
Enabled
[Hand on] Key enabled
[2]
Password
Avoid unauthorized start in Hand mode. If par. 0-40 is included in the My Personal Menu, then define the
password in
par. 0-65 Personal Menu Password
. Otherwise define the password in
par. 0-60 Main Menu Pass-
word
.
0-41 [Off] Key on LCP
Option:
Function:
[0]
Disabled
No function
[1]
*
Enabled
[Off] Key is enabled
[2]
Password
Avoid unauthorized stop. If par. 0-41 is included in the My Personal Menu, then define the password in
par.
0-65, Personal Menu Password
. Otherwise define the password in
par. 0-60, Main Menu Password
.
0-42 [Auto on] Key on LCP
Option:
Function:
[0]
Disabled
No function
[1]
*
Enabled
[Auto on] Key is enabled
[2]
Password
Avoid unauthorized start in Auto mode. If par. 0-42 is included in the My Personal Menu, then define the pass-
word in
par. 0-65, Personal Menu Password
. Otherwise define the password in
par. 0-60, Main Menu Pass-
word
.
3. Parameter Description
VLT
®
HVAC Drive Programming Guide
34
MG.11.C5.02 - VLT
®
is a registered Danfoss trademark
3