
Pa
r. No. #
Pa
rame
ter de
scri
pt
io
n
Def
ault value
(SR
= Size
rel
at
ed
)
4-
se
t-
up
FC 30
2
on
ly
Cha
nge duri
ng op
-
erat
ion
Co
nver-
sion index
Typ
e
1
6
-0*
General Stat
us
16-
00
Co
ntrol Word
0 N
/A
All se
t-
up
s
FA
LS
E
0
V2
16-
01
Re
fe
re
nc
e [Un
it]
0.
00
0 R
efe
re
nce
Fee
db
ackUni
t
All se
t-
up
s
FALS
E
-3
In
t3
2
16-
02
Re
fere
nce [
%
]
0.
0 %
Al
l set-
up
s
FALS
E
-1
In
t16
16-
03
St
atu
s W
ord
0 N
/A
All se
t-
up
s
FALS
E
0
V2
16-
05
Main Actu
al V
al
ue [%]
0.
00 %
Al
l set-
up
s
FALS
E
-2
N2
16-
09
Cust
om Re
ado
ut
0.
00 Custom
Re
ado
utUnit
All se
t-
up
s
FALS
E
-2
In
t3
2
16-1
*
M
o
tor
Stat
u
s
16-
10
Po
w
er
[k
W
]
0.
00 kW
All se
t-
up
s
FALS
E
1
In
t3
2
16-
11
Po
w
er [hp
]
0.
00 h
p
Al
l set-
up
s
FALS
E
-2
In
t32
16-
12
Mot
or V
ol
ta
ge
0.
0 V
All se
t-
up
s
FALS
E
-1
Ui
nt1
6
16-
13
Freq
uency
0.
0 H
z
All
se
t-
up
s
FA
LS
E
-1
U
in
t16
16-
14
Mot
or Curren
t
0.
00 A
All se
t-
up
s
FALS
E
-2
In
t3
2
16-
15
Freq
uency [%
]
0.
00 %
Al
l set-
up
s
FALS
E
-2
N2
16-
16
To
rque
[Nm]
0.
0 Nm
All se
t-
up
s
FALS
E
-1
In
t3
2
16-
17
Spe
ed
[R
PM
]
0 R
PM
Al
l set-
up
s
FALS
E
67
In
t32
16-
18
Mot
or Therma
l
0 %
All se
t-
up
s
FALS
E
0
Ui
nt8
16-
22
To
rque
[%]
0 %
All se
t-
up
s
FALS
E
0
In
t1
6
16-3
*
Dr
iv
e
S
tat
us
16-
30
DC Link Volta
ge
0 V
All se
t-
up
s
FA
LS
E
0
U
in
t1
6
16-
32
Brake
E
nerg
y /
s
0.
00
0 kW
All se
t-
up
s
FALS
E
0
Ui
nt3
2
16-
33
Brake
E
nerg
y /
2
min
0.00
0
kW
Al
l set-
up
s
FALS
E
0
U
in
t3
2
16-
34
Heatsink Temp.
0 °C
All se
t-
up
s
FALS
E
100
Ui
nt8
16-
35
Inve
rt
er
The
rmal
0 %
Al
l se
t-u
ps
FALS
E
0
U
int8
16-
36
Inv. Nom.
Curre
nt
SR
All se
t-
up
s
FALS
E
-2
Ui
nt3
2
16-
37
Inv.
Max.
Current
SR
All se
t-
up
s
FA
LS
E
-2
U
in
t32
16-
38
SL
Cont
rol
ler St
ate
0 N
/A
All se
t-
up
s
FALS
E
0
Ui
nt8
16-
39
Contro
l Card
Tem
p.
0
°C
Al
l set-
up
s
FALS
E
100
U
int8
16-
40
Lo
ggi
ng B
uffe
r
Fu
ll
[0] No
All se
t-
up
s
TRU
E
-
Ui
nt8
16-5* Ref.
& Feed
b.
16-
50
Externa
l R
efe
rence
0.
0 N
/A
All se
t-
up
s
FALS
E
-1
In
t1
6
16-52
Fe
edback [Unit]
0.
000 P
rocessCtrlUn
it
All
se
t-u
ps
FALS
E
-3
In
t32
16-
53
Digi Pot R
efe
rence
0.
00 N/A
All se
t-
up
s
FALS
E
-2
In
t1
6
16-54
Fe
edback 1 [Un
it]
0.
000 P
rocessCtrlUn
it
All
se
t-u
ps
FALS
E
-3
In
t32
16-
55
Feed
back 2 [U
ni
t]
0.
000 P
rocessCtrlUn
it
All se
t-
up
s
FALS
E
-3
In
t3
2
16-56
Fe
edback 3 [Un
it]
0.
000 P
rocessCtrlUn
it
All
se
t-u
ps
FALS
E
-3
In
t32
16-
58
PI
D
Ou
tp
ut
[%
]
0.
0 %
All se
t-
up
s
TRU
E
-1
In
t1
6
5.1.16
.
16-**
Dat
a Readouts
5. Parameter Lists
VLT
®
HVAC Drive Programming Guide
260
MG.11.C5.02 - VLT
®
is a registered Danfoss trademark
5