Pa
r. No. #
Pa
rame
ter de
scri
pt
io
n
Def
ault value
4-
se
t-
up
FC 30
2
on
ly
Cha
nge duri
ng op
-
erat
ion
Co
nver-
sion index
Typ
e
21-0* Ex
t. CL Aut
o
tu
ning
21-
00
Cl
osed
L
oop
Type
[0
] Aut
o
2 set-
ups
TRUE
-
Uint8
21-
01
PI
D
Pe
rf
or
m
an
ce
[0] No
rmal
2 se
t-up
s
TRU
E
-
Ui
nt8
21-
02
PI
D Output Ch
ang
e
0.
10 N/A
2
se
t-up
s
TR
U
E
-2
U
in
t1
6
21-
03
Mini
mum Feedback Level
-999
999.
000
N/
A
2 se
t-up
s
TRU
E
-3
In
t3
2
21-
04
Maxim
um
Fee
db
ack Le
vel
999999
.00
0
N/
A
2 se
t-up
s
TR
U
E
-3
In
t32
21-
09
PI
D
A
uto
tu
ni
ng
[0
] Di
sabl
ed
All se
t-
up
s
TRU
E
-
Ui
nt8
21-1
*
Ext
. CL 1
Re
f.
/Fb.
21-
10
Ex
t. 1 Ref
./
Feed
back
U
nit
[1
] %
All se
t-
up
s
TRU
E
-
Ui
nt8
21-
11
Ext.
1
Mi
nim
um
R
efe
rence
0.0
00
Ex
tPI
D
1U
ni
t
Al
l set-
up
s
TR
U
E
-3
In
t32
21-
12
Ext. 1
Maxi
mum
Reference
100.
000 Ex
tP
ID
1Uni
t
All se
t-
up
s
TRU
E
-3
In
t3
2
21-13
Ex
t.
1 R
efe
rence
Source
[0] No funct
ion
Al
l se
t-u
ps
TRUE
-
Uint8
21-
14
Ext. 1
Feed
ba
ck
So
urce
[0] No
funct
io
n
All se
t-
up
s
TRU
E
-
Ui
nt8
21-
15
Ext.
1
Setp
oi
nt
0.0
00 Ex
tPI
D
1U
ni
t
Al
l set-
up
s
TR
U
E
-3
In
t32
21-
17
Ex
t.
1 R
efe
rence
[
U
nit]
0.0
00 Ex
tPI
D
1U
ni
t
All se
t-
up
s
TRU
E
-3
In
t3
2
21-
18
Ext.
1
Fe
ed
ba
ck
[Uni
t]
0.0
00
Ex
tPI
D
1U
ni
t
Al
l set-
up
s
TR
U
E
-3
In
t32
21-
19
Ext.
1 Output [%]
0 %
All se
t-
up
s
TRU
E
0
In
t3
2
21-2
*
Ext
. CL 1
PI
D
21-
20
Ex
t. 1
Normal/Inverse
Con
trol
[0] No
rmal
All se
t-
up
s
TRU
E
-
Ui
nt8
21-
21
Ext.
1
P
ro
po
rtio
nal
Gai
n
0.
01
N/A
Al
l set-
up
s
TR
U
E
-2
U
in
t1
6
21-
22
Ext.
1
I
nte
gr
al
T
ime
10000
.00
s
All se
t-
up
s
TRU
E
-2
Ui
nt3
2
21-
23
Ext.
1
Di
ffe
rentat
io
n
Ti
me
0.
00
s
Al
l set-
up
s
TR
U
E
-2
U
in
t1
6
21-
24
Ext.
1
D
if.
Gai
n L
imi
t
5.
0 N
/A
All se
t-
up
s
TRU
E
-1
Ui
nt1
6
21-3
*
Ext
. CL 2
Re
f.
/Fb.
21-
30
Ex
t. 2 Ref
./
Feed
back
U
nit
[1
] %
All se
t-
up
s
TRU
E
-
Ui
nt8
21-
31
Ext.
2
Mi
nim
um
R
efe
rence
0.0
00
Ex
tPI
D
2U
ni
t
Al
l set-
up
s
TR
U
E
-3
In
t32
21-
32
Ext. 2
Maxi
mum
Reference
100.
000 Ex
tP
ID
2Uni
t
All se
t-
up
s
TRU
E
-3
In
t3
2
21-33
Ex
t.
2 R
efe
rence
Source
[0] No funct
ion
Al
l se
t-u
ps
TRUE
-
Uint8
21-
34
Ext. 2
Feed
ba
ck
So
urce
[0] No
funct
io
n
All se
t-
up
s
TRU
E
-
Ui
nt8
21-
35
Ext.
2
Setp
oi
nt
0.0
00 Ex
tPI
D
2U
ni
t
Al
l set-
up
s
TR
U
E
-3
In
t32
21-
37
Ex
t.
2 R
efe
rence
[
U
nit]
0.0
00 Ex
tPI
D
2U
ni
t
All se
t-
up
s
TRU
E
-3
In
t3
2
21-
38
Ext.
2
Fe
ed
ba
ck
[Uni
t]
0.0
00
Ex
tPI
D
2U
ni
t
Al
l set-
up
s
TR
U
E
-3
In
t32
21-
39
Ext.
2 Output [%]
0 %
All se
t-
up
s
TRU
E
0
In
t3
2
21-4
*
Ext
. CL 2
PI
D
21-
40
Ex
t. 2
Normal/Inverse
Con
trol
[0] No
rmal
All se
t-
up
s
TRU
E
-
Ui
nt8
21-
41
Ext.
2
P
ro
po
rtio
nal
Gai
n
0.
01
N/A
Al
l set-
up
s
TR
U
E
-2
U
in
t1
6
21-
42
Ext.
2
I
nte
gr
al
T
ime
10000
.00
s
All se
t-
up
s
TRU
E
-2
Ui
nt3
2
21-
43
Ext.
2
Di
ffe
rentat
io
n
Ti
me
0.
00
s
Al
l set-
up
s
TR
U
E
-2
U
in
t1
6
21-
44
Ext.
2
D
if.
Gai
n L
imi
t
5.
0 N
/A
All se
t-
up
s
TRU
E
-1
Ui
nt1
6
5.1.19
.
21-**
Ext
.
Closed
Loop
5. Parameter Lists
VLT
®
HVAC Drive Programming Guide
264
MG.11.C5.02 - VLT
®
is a registered Danfoss trademark
5