SiBE811120
Operation Manual
Photocatalytic Air Purifier L-Series
27
20
CAUTION
UNIT2
Notes
4) Streamer unit
Wipe
Reattach the streamer unit as before.
2) Ionised wire (8 locations)
4) Streamer unit
: Plastic parts
Cotton swab
ATTENTION
Wear rubber gloves when wiping or rubbing the units.
• Hands can be cut on the opposing pole plates and ionised wires.
There are ionised wires on the rear of the opposing pole plates. Be careful not to snap these wires when removing and attaching the units.
• If the unit is operated with broken ionised wires, the “UNIT1” lamp lights. While the lamp is lit, dust collecting capacity is low.
• If any ionised wire is accidentally cut, it is necessary to replace the ionised wire with a new one. Consult your dealer.
(Do not replace the ionised wire by yourself.)
Open the front panel and pull out
the streamer unit.
• Do not remove the screws from the ionising frame or UNIT2.
This may lead to damage.
For details, see 4)
below.
• Clean UNIT1 and UNIT2 somewhere which can be wet such as in a shower room or
kitchen sink.
• For stubborn dirt, soak UNIT1 and UNIT2 in lukewarm water or water in which neutral
liquid detergent (i.e., kitchen cleaner, etc.) has been dissolved.
• Use the amount of neutral liquid detergent indicated in the instructions for the detergent.
• Do not use powdered, alkaline or acidic cleaner, and do not rub with hard brushes, etc.
It may lead to deformation and damage.
• If the needles inside UNIT2 are deformed, deodorising capacity diminishes.
• If detergent remains on UNIT1 or UNIT2, the “UNIT1” and “UNIT2” lamps do not go off
after cleaning, therefore rinse off the detergent well.
• Do not leave any lint from cleaning cloths behind. Lint may lead to malfunctions.
• Plastic parts may deform or discolour if exposed to direct sunlight.
• If water remains on UNIT1 or UNIT2, even in small quantities, the “UNIT1” and “UNIT2”
lamps do not go off after cleaning, therefore dry them throughly in the shade.
Wear rubber
gloves.
• Remove dirt from the ionised wires and surrounding plastic
parts with a soft piece of cloth.
Wear rubber
gloves.
Clean the ionised wires
without dislodging them
from the V-groove.
* Wipe the ionised wires gently.
Pulling on them forcefully may cause them to snap.
• Wipe the needles with a cotton swab or a soft piece of cloth if
they are dirty.
• Remove dirt from plastic parts ( ) in internal areas with a
cotton swab or a soft piece of cloth.
• Do not remove the screws.
Wear rubber
gloves.
Wipe the needles
gently from the base
to the tip.
Do not touch
the needles.
• Operation can be performed safely without the streamer unit installed on the main unit, but this degrades the deodorising performance. Use
the main unit after the streamer unit is installed.
* If the needles are deformed, deodorising capacity diminishes.