Removal Procedure
SiBE811120
56
Photocatalytic Air Purifier L-Series
9.7
Removal of Power Cord
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Remove the 2 screws
from the front side.
2
Pull the base ASSY out.
Peel off the filament tape
and release the ferrite core
at the backside.
3
Remove the switch
cover.
(R12383)
Base ASSY
(R14656)
Ferrite core
Filament tape
(R12386)
Ferrite core
Switch cover
(R14657)