3. Remove the pre-filter.
When reassembling, fit the
pre-filter as the “FRONT”
mark comes front.
1
Pull the recessed part
of the pre-filter upper
section and unfasten
the right and left hooks
(4 in total).
2
Remove the pre-filter.
4. Remove the plasma
ionizer unit.
To prevent the air purifier
from falling down, support
the air purifier while
removing the plasma ionizer
unit.
1
Hold the handles of the
plasma ionizer unit. Pull
the plasma ionizer unit
to unfasten the hooks
and lift it up to remove.
Step
Procedure
Points
(R12334)
Hook
Hook
Pre-filter
Recessed part
with “FRONT”
mark
(R12335)
When reassembling, fit the 4
hooks of the pre-filter into the
4 holes of the plasma ionizer
unit.
The upper left hook is
shaped differently from the
others.
(R12336)
Handle
Plasma ionizer unit
Hook