Wiring Check after Replacing PCBs
SiBE811120
36
Photocatalytic Air Purifier L-Series
8. Wiring Check after Replacing PCBs
Check the following points after replacing the PCBs.
Wiring check mode using the remote controller
(1) Insert the power plug.
(2) Press the [OFF TIMER] button within 2 seconds.
(3) If the connection is correct, all the lamps light up after about 5 seconds.
If there is any wrong connection, correct it.
z
When the UNIT1 lamp lights up, the wiring to the plasma ionizer is incorrect.
z
When the UNIT2 lamp lights up, the wiring to the streamer unit is incorrect.
z
When the UNIT1 and UNIT2 lamps light up at the same time, the wirings to the plasma
ionizer and the streamer unit are incorrect.
(4) Insert the power plug again, then the normal operation starts.
(R14652)
OFF TIMER button
UNIT1 lamp
UNIT2 lamp
(R14653)