18
UNIT1
Opposing pole plates
Ionised wire
1
2
Ionised wire
Knob
Knob
(white)
1
Knob
(white)
2
Be careful not to cut the
internal ionised wires.
Opposing
pole plates
Removing and attaching the opposing pole plates
CAUTION
Wear rubber gloves to remove and attach the opposing pole plates. Hands can be cut on the opposing pole plates and ionised wires.
Ionising frame
Front panel
Remove
Remove the front panel and UNIT1.
Page 17.
Remove the opposing pole plates from
the rear of UNIT1.
Pinching the sets of knobs
on the right and left at the
same time makes it easier
to remove the opposing
pole plate.
Ionising frame
(green)
Page 17.
Attach UNIT1 and the front panel.
Arrow
Wear rubber
gloves.
The opposing pole plates have no difference between the
upper and the lower, or between the right and the left.
Attach them so that the arrow is visible.
Attach the opposing pole plates.
Attach
1) Fit the opposing pole plate over the knobs (2 sets on the
right and left) on the ionising frame.
Ionising frame
Opposing
pole plates
2) Insert securely until it clicks.
3) Attach the other opposing pole plate.
• Pinching together the white and green knobs (2 sets on
the right and left), lift the opposing pole plate up and
remove it.
Wear rubber
gloves.