6.1 Wiring
diagrams
400 D.O.L 50Hz
up to 3kW 2P / 2.2kW 4P
380-480 D.O.L 60Hz
up to 3kW 2P / 2.2kW 4P
400 D.O.L
50Hz from 4kW 2P / 3kW 4P and up
380-480 D.O.L 60Hz from 4kW 2P / 3kW 4P and up
230 D.O.L.
50Hz up to 3kW 2P / 2.2kW 4P
220-277 D.O.L. 60Hz up to 3kW 2P / 2.2kW 4P
Without sensor
Without sensor
Sensor Version
400 Y/D 50Hz
380-480 Y/D 60Hz
Without sensor
Sensor Version
230 Y/D
50Hz
220-277 Y/D
60Hz
Without sensor
Sensor Version
6.2 Electric panel level switches
During operation the electropump must be immersed in the pumped liquid. It is necessary to install a
control system with level switches (level probes or floats or other appliances) that ensure the minimum
level of liquid and protect the electropump against dry running.
When installing the level switches, observe the following points:
To prevent air intake and vibrations install the
stop level switch
in such a way that the pump is stopped
before the liquid level is lowered below the top of the cable entry.