background image

x

x

x

x

x

x

x

x

x

x

 

          8          7           6

10        9

1          2           3         4           5

12:34

C1

Th

CH A  MANUAL  CH B

CLOCK

TIMER

DAY

HOUR

CLS/RCL

MIN

CH A  ON

ON

AUTO

AUTO

OFF

OFF  CH B  

CH A     CH B

RESET

Dual Clock (S2)  and  

Digital Thermostat Versions

3-PHASE ELEMENTS  
MUST BE WIRED IN 
STAR FASHION

N

3 PHASE ELEMENTS

“All STAINLESS STEEL”

INSTRUCTIONS

Installation & Maintenance

DAIRY WATER HEATER

Cotswold Dairy Equipment Co Ltd

Avenue 3  Station Lane

Witney    Oxford    OX28  4BP   

 UK

Tel +44 (0)1993  774567

Fax +44 (0) 1993 771776

e-mail  [email protected]

www.cotswold-dairy.co.uk

CE

MADE IN ENGLAND

COTSWOLD

ELEMENTS AND THERMOSTATS

WH9

3kw

1 phase 18” & stat pocket

WH9A

3kw

1 phase 14” & stat pocket

WH9B

3kw

1 phase   9” & stat pocket

WH9D

4kw

1 phase 14” & stat pocket

WH9F

3kw

1 phase 11”  & stat pocket

WH10

4.8kw

1 phase 18” & stat pocket  

WH10A

4.8kw 

3 phase 18” & stat pocket

WH11

6kw

1 phase 18” & stat pocket

WH12

6kw

3 phase 18” &  stat pocket

WH12A

9kw

3 phase 18” no stat pocket

WH13

Hi Range Stat 30° - 110/120°

SET CURRENT TIME
Press and Hold Down CLOCK button whilst setting hours 
and minutes to input current time

SET HEATER ON/OFF TIMES
Press and release TIMER until C1 appears on right 
and 1-ON comes up at left, set first element ON time by 
pressing HOUR and MIN

Press Timer again,  1-OFF will appear at left
set first element OFF time by pressing HOUR and MIN

Press Timer again,  2-ON will appear at left
set second element OFF time by pressing HOUR and MIN

Press Timer again,  2-OFF will appear at left
set second element OFF time by pressing HOUR and MIN

(repeat above steps for third and fourth on/offs if needed
if not required, press TIMER repeatedly to step through 
3on/off and 4on/off)

SET WATER SOLENOID to re-fill heater
Press and release TIMER until C2 appears on right 
and 1-ON comes up at left, 
set first Solenoid OPEN time by pressing HOUR and MIN

Press TIMER again,  1-OFF will appear at left
set first SOLENOID OFF (close) time by pressing HOUR and 
MIN
(this will shut water solenoid - allow 2 - 3 hours to refill 
heater)

Press  TIMER again and 2-ON comes up at left, set second 
SOLENOID OPEN time by pressing HOUR and MIN

Press Timer again,  2-OFF will appear at left,
set Second SOLENOID OFF (close) time by pressing HOUR 
and MIN,  (this will again shut water solenoid - allow 2 - 3 
hours to refill heater)

(repeat above sequences to set thirdon/offs if required,(no 
fourth setting) if not required, press TIMER to step through 
3on/off and return to C1)      

Finalise settings by pressing CLOCK

SET AUTO OPERATION
Press CH A until line at bottom of display is above AUTO, 
repeat for CH B

if stepping from ON to AUTO, timing starts immediately, 
i
f stepping from OFF to AUTO timing will start at NEXT 
clock point

CLOCK CONNECTIONS

Channel A (Heater Element) 

Series 1 (Up to Approx Aug’08): 7 & 6

Series 2 (After Approx Aug’08): 2 & 3

Channel B (Water Inlet Solenoid)

Series 1 (Up to Approx Aug’08): 10 & 9

Series 2 (After Approx Aug’08): 1 & 2

Illustration is of Series 2 Clock, fitted August 2008 on

(both types of clock have 

same set-up, but different connections)

TO SET DIGITAL CLOCK (for every day use) 

See clock’s own manual for other settings. 

     THIS IS A 24 HOUR CLOCK

Отзывы: