4 of 130
after removing the shipping boards. Once the skid
boards are removed there is 3” (76.2 mm) from base
flange to the floor with the leveling legs screwed all
the way in.
Once the vender is unpacked, check the “B” Tray area
for any additional parts, price/product labels,
service/operation manual or other information
concerning factory-equipped accessories such as coin
mechanism and validator.
It is recommended the vender be vend tested before
shipping to the location. In programming see ”Test
Mode”, # 9 “Test Vend” to perform test vends.
Note: Remove tape from ends of top
lamp in the top lamp assembly after
placing the Vender on location, but
before plugging the Vender in to an AC
power supply.
WARNING: TO AVOID THE
POSSIBILITY OF A FIRE
HAZARD, DO NOT STORE
ANYTHING OR ALLOW
DEBRIS OF ANY KIND TO
ACCUMULATE IN THE
BOTTOM OF THE SERVICE
AREA, IN AND AROUND THE
REFRIGERATION
COMPARTMENT OF THE
CABINET, OR IN FRONT OF
THE EVAPORATOR AND
CONDENSER COILS.
WARNING: ENSURE THAT
POWER IS DISCONNECTED
FROM THE VENDER BEFORE
INSPECTING OR REPLACING
THE LAMPS, OTHER
ELECTRICAL COMPONENTS,
OR WORKING WITH OR
ADJUSTING THE VENDING
MECHANISM. FAILURE TO
COMPLY WITH THESE
INSTRUCTIONS MAY
SUBJECT THE USER TO THE
RISK OF ELECTRICAL
SHOCK OR MECHANICAL
INJURY, WHICH CAN BE
SERIOUS OR FATAL.
ELECTRICAL POWER NEEDED
Refer to the cabinet serial number plate to determine
the correct voltage and frequency for the machine. In
the US and Canada this is 120Vac, 60Hz, 1P. In
Europe, Australia, and other export countries, this is
220/230/240Vac, 50Hz, 1P depending upon your
country voltage. The serial plate also specifies the
ampere rating of the machine. This machine must be
plugged into a properly rated receptacle with its own
circuit protection (fuse or circuit breaker).
Equipment Nominal Power Requirements
120V / 10.2 A = *1224W (1.224kw)
220V / 5.8 A = *1276W (1.276kw)
240V / 5.8 A = *1392W (1.392kw)
*Note: Watts = V X A
DO NOT USE AN EXTENSION CORD.
POWER SUPPLY CORD and GROUNDING
REQUIREMENTS
In accordance with the National Electrical Code and
Underwriters Laboratories Inc., domestic vending
machines are equipped with a three-wire power
supply cord and Ground Fault Circuit Interrupter
(GFCI). The GFCI device is provided as part of the
power supply cord and is either incorporated directly
into the plug or mounted on the cord adjacent to the
plug.
WARNING
•
The
GFCI
protects against current
leakage caused by ground faults.
The GFCI is not designed to protect
against over current or short
circuits.
•
DO NOT
use the TEST and RESET
buttons on the GFCI as an ON/OFF
switch.
•
The vending machine supply cord
MUST
be plugged directly into a
properly grounded, 3 wire
receptacle that is properly
protected by a fuse or circuit
breaker. If the receptacle will not
accept the power cord plug, it must
be replaced with a properly
grounded, 3 wire receptacle in
accordance with the National
Electrical Code and Local Codes
and Ordinances. The work should
be done by a qualified electrician.
DO NOT USE A 3 WIRE TO 2
WIRE ADAPTOR
Содержание BevMax MEDIA