Page
30
of
128
Error
Description
Probable
Cause
Possible
Solutions
Cooling System
The control board is reporting that the refrigeration
Check for a bad temperature sensor.
Not Cooling.
system is not functioning.
Check for other errors that would cause the
refrigeration system to have been shut down
by the board.
Cabinet Too Hot.
The control board is reporting that the cabinet is
Check for an accurate temperature reading.
operating at three degrees, or more, above the
Check refrigeration system for proper function
allowed parameter.
(clean screens, condenser also distance from rear wall).
Check for proper fan operation.
Cabinet Too Cold.
The control board is reporting that the cabinet is
Check for an accurate temperature reading.
operating at three degrees, or more, below the
Check refrigeration system for proper function
allowed parameter.
(clean screens, condenser also distance from rear wall).
Check for proper fan operation.
Card Reader Manuf Trans
The card reader has reported an error in
Check the card reader for proper function.
Error.
transmitting
data. Replace
the
card
reader.
Card Reader Service Error.
An internal error has occurred within the card
Reset the card reader and retry.
reader.
Replace
the
card
reader.
Card Reader Manufact Error.
An internal error has occurred within the card
Reset the card reader and retry.
reader.
Replace
the
card
reader.
Card Reader Failed OOS Error. An internal error has occurred within the card
Reset the card reader and retry.
reader.
Replace
the
card
reader.
Card Reader Comms OOS
An internal error has occurred within the card
Reset the card reader and retry.
Error.
reader.
Replace
the
card
reader.
Card Reader Jam OOS Error. An internal error has occurred within the card
Reset the card reader and retry.
reader.
Replace
the
card
reader.
Card Reader Manufact OOS
An internal error has occurred within the card
Reset the card reader and retry.
Error.
reader.
Replace
the
card
reader.
Содержание BevMax MEDIA
Страница 1: ...0 of 130 English 80390486 Tier 3 ...