Error
Description
Probable
Cause Possible
Solutions
Stuck Keys Fatal.
Stuck keys on keypad or shorted connections/harness. Check
connectors to be properly installed.
Check harness for damage.
Replace the keypad.
No Monetary Device Fatal.
The control board has not been able to detect a
Check connectors to be properly installed.
working monetary device.
Check harness for damage.
Check for faulty bill validator/harnessing.
Retest without the bill validator and harnessing
installed.
Replace the coin mechanism.
Coin Mech No Comms.
No Communications are occurring between the
Check connectors to be properly installed
coin mechanism and the control board.
Check harness for damage
Retest without the bill validator and harnessing
installed.
Replace the coin mechanism.
Coin Mech ROM Error
Coin Mech ROM Error
Replace the coin mechanism.
Coin Mech Acceptor
Coin Mech Acceptor Unplugged.
Check the connections within the coin mechanism
Unplugged.
Replace
the
coin
acceptor.
Replace the coin Mechanism.
Coin Mech Acceptor
Coins or other items are stuck in the acceptor
Remove the coins or other items from the acceptor.
Jammed.
causing the gate to remain open.
Replace the acceptor.
Replace the coin mechanism.
Coin Mech Payout Jammed.
Coin pay out motor or solenoid is stuck in cycle.
Check for and remove bent coins or other items
causing the jam.
Replace the coin mechanism.
Coin Mech Sensor Error.
Bad coin mechanism sensor.
Check for an item causing a blockage and remove.
Replace the coin mechanism.
Coin Mech All Tubes Error.
Coin mechanism not sensing any pay out tubes.
Check for proper pay out cassette placement.
Replace the payout cassette.
Replace the coin mechanism.