ID-FLX Lite Global Guide
80
6.3.1 List of ECU diagnostic codes
Faultcode
Diagnostic code
Faultcode
Diagnostic code
Faultcode
Diagnostic code
51
ThrottlePos
158
BattPotential
636
PositionSensor
91
AccelPedalPos
168
ElectricalPot
637
TimingSensor
94
FuelDelPress
172
AirInlet Temp
639
J1939 CAN Bus
97
WaterInFuelInd
174
Fuel Temperat
651
InjectorCyl#1
98
EngineOilLevel
175
EngOil Temp
652
InjectorCyl#2
100
EngOil Press
189
RatedEngSpeed
653
InjectorCyl#3
101
CrankcasePress
190
EngineSpeed
654
InjectorCyl#4
102
Boost Press
231
J1939 Datalink
655
InjectorCyl#5
105
Intake Temp
237
VIN
656
InjectorCyl#6
106
AirInletPress
515
EngDesOpSpeed
677
EngStartRelay
107
AirFiltDifPres
620
5V SupplyFail
898
RequestedSpeed
108
BarometricPres
626
PrehActuator
970
AuxEngSdSwitch
110
EngCool Temp
628
EMSProgFailure
971
EngDerateSwtch
111
Coolant Level
629
Controller#1
1109
EngSdApproach
153
CrankcasePress
630
CalibrMemFail
1110
Engine Sd
Note:
ID-Lite controller doesn’t support J1587 diagnostic line on Volvo engines. This can cause in some cases
a J1939 alarm message FC:000608 due to missing J1587 bus. Contact your Volvo distributor to update ECU
firmware.
For Scania Fault codes (FC) are displayed. Following messages are available for particular groups of Fault
codes:
Faultcode
Diagnostic code
Faultcode
Diagnostic code
0×1000
Overspeed
0×6702
AlternatorChrg
0×1100
EngSpdSensor1
0×6A00
ExhaustBrkAct
0×1200
EngSpdSensor2
0×B000
OilPressProt
0×2000
WtrTempSensor
0×B100
CoolantLevProt
0×2100
ChrgAirTmpSens
0×B200
OverheatCoolWt
0×2200
ChrgAirPrsSens
0×B300
EmergencyStop
0×2300
OilTempSensor
0×B501
CoolantLevel
0×2400
OilPressSensor
0×C000
PDEInjctorCyl1
0×2600
SensorSupply1
0×C100
PDEInjctorCyl2
0×2700
SensorSupply2
0×C200
PDEInjctorCyl3
0×2800
ExtrAnalogInp
0×C300
PDEInjctorCyl4
0×3200
BatteryVoltage
0×C400
PDEInjctorCyl5
0×3300
CAN msg not ok
0×C500
PDEInjctorCyl6
0×3403
CAN version
0×C600
PDEInjctorCyl7
0×4300
HWWatchdog
0×C700
PDEInjctorCyl8
Содержание InteliDrive FLX LITE
Страница 19: ...ID FLX Lite Global Guide 19 4 3 Terminal diagram and dimension ...
Страница 21: ...ID FLX Lite Global Guide 21 Example Default analog output curves ...
Страница 22: ...ID FLX Lite Global Guide 22 Example Wiring for Dacon gauges and IL NT AOUT8 ...
Страница 43: ...ID FLX Lite Global Guide 43 When you finish with adjusting the values click OK and Write to controller ...
Страница 44: ...ID FLX Lite Global Guide 44 5 2 Binary inputs and outputs ...
Страница 57: ...ID FLX Lite Global Guide 57 5 14 Display screens and pages structure ...
Страница 83: ...ID FLX Lite Global Guide 83 7 Communication 6 back to Table of contents ...
Страница 92: ...ID FLX Lite Global Guide 92 10 Appendix 10 2 Extension modules 225 6 back to Table of contents ...