Specifications
7600
7600C
Case Temperature
1
0°C to 50°C (32°F to 122°F)
Storage Temperature
-20°C to 80°C (-4°F to 176°F)
Humidity
< 80% non-condensing
Protection
IP67 with all cables properly attached (or the provided connector plug installed), the IP67-
rated cover properly installed, and the Micro SD card cover fastened in place.
Shock (Shipping and
Storage)
IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z) axis) 80 Gs (800m/s
2
at
11ms, half-sinusoidal) with cables or cable plugs and a 150 gram or lighter lens attached.
Vibration (Shipping and
Storage)
2
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to 500 Hz
at 100m/s
2
/ 15mm) with cables or cable plugs and a 150 gram or lighter lens attached.
Regulations/Conformity CE, FCC, KCC, TÜV SÜD NRTL, EU RoHS, China RoHS
1
To verify case temperature, use the EV GetSystemConfig(“Internal.Temperature”) Extended Native Mode command or GetSystemConfig
(“Internal.Temperature”) spreadsheet function. When issued, it returns the vision system internal temperature in degrees Celsius, which is
approximately 3 to 5 degrees above the vision system case temperature. For more information, see the
In-Sight
®
Explorer Help
file. A thermal
scanner can also be used to determine the vision system case temperature. Additional cooling measures are required if the case temperature
cannot be kept below 50°C. Examples of such measures include: extra heat sinking and/or air movement.
2
Before you ship this product or any machinery that contains it, remove lenses that weigh more than 150 grams.
74
Specifications
Содержание In-Sight 7600
Страница 1: ...In Sight 7000 Gen2 Series Vision System Reference Guide 2020February06 Revision 5 8 1 2...
Страница 42: ...42 Installation...
Страница 43: ...43 Installation...
Страница 113: ......