Acquisition Trigger Input
The vision system features one acquisition trigger input, which is optically isolated. You can configure the acquisition
trigger input to trigger from an NPN (current sinking) or PNP (current sourcing) device.
Specification
Description
Voltage
ON: 15 to 28V DC (24DC nominal)
OFF: 0 to 5VDC (11.5VDC nominal threshold)
Current
(Typical)
ON: 2.6mA to 4.9mA from 15 to 28V input
OFF: < 830µA for < 5VDC input
Resistance: ~6 kOhms
Delay
190µs maximum latency between leading edge of trigger and start of acquisition. Input pulse should be
a minimum of 1ms wide.
l
To trigger from an NPN type photoelectric sensor or PLC output, connect COMMON IN to +24VDC and connect
TRIGGER to the output of the photoelectric sensor. When the output turns ON, it pulls TRIGGER down to 0VDC,
turning the opto-coupler ON. For more information, refer to
l
To trigger from a PNP photoelectric sensor or PLC output, connect TRIGGER to the output of the photoelectric
sensor and connect COMMON IN to 0VDC. When the output turns ON, it pulls TRIGGER up to +24VDC, turning
the opto-coupler ON. For more information, refer to