Remove the Illumination Accessory PCB
If the illumination accessory (ISLM-7000-WHI) must be uninstalled from the vision system, complete the following steps
to safely remove the PCB and avoid damage to the vision system.
CAUTION
:
Do not hot-plug the illumination accessory. Verify the vision system is not receiving power when
connecting or disconnecting the illumination accessory. Failure to remove power during this procedure may result
in damage to the vision system and/or the illumination accessory.
1. Remove power from the vision system.
2. Use a 2mm hex wrench to remove the four spacer screws. Remove the spacer.
3. The vision system faceplate includes two lift points on either side of the PCB. Position an insulated extractor tool
(for example, Jonard Tools S-340 DIP/IC Extractor) under the edges of the PCB.