5. Install the autofocus module.
CAUTION
:
Do not hot-plug the autofocus module. Verify the vision system is not receiving power when
connecting or disconnecting the autofocus module.
Note
: If a different lens is required, it should be installed in the autofocus module before the autofocus
module is installed to the vision system. For more information, see
Replace the M12 Autofocus Lens
a. There are two alignment pins on the base of the autofocus module. Seat the pins into the vision system
faceplate.
b. There are three captive screws in the autofocus module. Partially thread the screws into the vision system
faceplate using a 1.5mm hex wrench.
c. Once threaded, torque the captive screws to 0.5 Nm (4.43 in-lb) using a torque screwdriver with a 1.5mm
hex torque bit capable of reaching 15mm into a 2.5mm diameter hole. For example, Wiha Tools 1.5mm
Hex Metric Torque Blade (SKU 28545) used with the Adjustable Torque Handle (SKU 28550).
35