Installation
Read this section to learn how the vision system connects to its standard components and accessories. For a list of
options and accessories, contact your Cognex sales representative.
Note
: Cables are sold separately.
CAUTION
:
All cable connectors are keyed to fit the connectors on the vision system. Do not force the connections
or damage may occur.
Install the Lens, Lighting and Cover
You can choose between a variety of different C-Mount and S-Mount/M12 lenses and covers to install to the vision
system. Refer to
In-Sight Lenses, Lights and Covers
and
DataMan Lenses, Lights and Covers
for
a complete list of options and accessories.
Install the C-Mount Lens and Cover (COV-7000-CMNT or
COV-7000-CMNT-EX)
Complete the following steps to install a C-Mount lens and cover to the vision system. The C-Mount covers are optional
accessories and required for IP67 protection.
Note
:
l
When using a C-Mount lens, the following restrictions apply:
l
Maximum thread length is 5.25mm.
l
The C-Mount lens threads and body cannot protrude more than 6.5mm in length into the vision
system when screwed in unless the diameter of the back lens is smaller than 14.75mm. If the C-
Mount lens threads and body protrude more than 6.5mm, you can add a spacer between the lens
and vision system. However, the spacer decreases the working distance.
l
If using the COV-7000-CMNT cover, the maximum lens length is 41mm, the maximum lens body diameter is
36.5mm and the maximum diameter including locking screws is 47mm.
l
If using the COV-7000-CMNT-EX cover, the maximum lens length is 62mm, the maximum lens body
diameter is 36.5mm and the maximum diameter including locking screws is 46.5mm.
CAUTION
:
If installing a C-Mount cover, the illumination accessory (ISLM-7000-xxx) PCB should not be installed to
the vision system. Refer to
Remove the Illumination Accessory PCB
for steps to safely remove the
PCB and avoid damage to the vision system.
1. Remove the rubber faceplate covering the image sensor window, if present.
2. Remove the protective film covering the threaded lens opening, if present.
3. Place the adapter on the faceplate of the vision system. Insert the four adapter screws and tighten; the maximum
torque is 0.90 Nm (8 in-lb).
4. Thread the lens into the vision system.