3-59
Cisco ONS 15200 Installation, Setup, and Test Manual
78-13765-01
Chapter 3 Installation
Step 3
Inhibit the board.power alarm if you are only using one power source.
Step 4
Connect the new SCU power to power connector PS1 or PS2 (or both if redundant power supplies are
used) and verify that no red LED is lit.
Step 5
To break the ring, disconnect the fiber connecting the ONS 15252 MCU to the ONS 15201 SCU A-side
IN and OUT ports, or the fiber between two SCUs.
Step 6
To connect the new SCU:
a.
Connect the A-side IN and OUT ports on one node to the B-side OUT and IN ports on an adjacent
node.
b.
Connect the B-side IN and OUT ports of the other node to the A-side OUT and IN ports of the first
node.
Step 7
Connect the client ports of the new SCU to the appropriate client equipment.