3-32
Cisco ONS 15200 Installation, Setup, and Test Manual
78-13765-01
Chapter 3 Installation
Figure 3-23 An ONS 15252 MCU with the passive optical shelf door open
Step 2
Align the A-side LM with the far left position (if applicable) and the B-side LM with the far right
position (if applicable) in the passive optical shelf. Insert them as shown in
Note
Normally an MCU is equipped with two LMs, but under some circumstances there may be
only one LM or no LM at all.
Step 3
Make sure the crossbar at the back of the passive optical shelf and the groove in the back of the LMs fit
together.
Step 4
Push the button at the bottom front of the LMs and snap the LMs into place.
54865