3-37
Cisco ONS 15200 Installation, Setup, and Test Manual
78-13765-01
Chapter 3 Installation
Step 2
Carefully slide the TM into the passive optical shelf. Be sure the groove on the back of the TM connects
with the passive optical shelf crossbeam.
Step 3
Push down on the TM retainer button located on the TM front panel and snap the TM into place.
Step 4
If applicable, repeat Steps
for the other TM.
Procedure: Install a Connection Module X in Two ONS 15252 MCUs
Note
Use this procedure if you are using two or more installed assembled-to-order (ATO) MCUs.
Step 1
Disconnect the MU duplex connector from the TM you will replace.
Step 2
Put protective caps on the MU duplex connector.
Step 3
Remove a TM module from the passive optical shelf of the first MCU.
Step 4
Position one side of the CMX (
) in the passive optical shelf of the first MCU where the TM
was removed.
Figure 3-27 Side view of a CMX module
Step 5
Carefully insert the half CMX into the passive optical shelf. Be sure the groove on the back of the module
interlocks with the crossbeam located in the passive optical shelf.
Step 6
Snap the CMX into place by pushing the retainer located at the bottom of the CMX.
Step 7
Remove the dust plugs located on the CMX duplex MU-MU adapter.
54905
Содержание ONS 15200 Series
Страница 26: ...2 6 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Chapter 2 Pre Installation Procedures ...
Страница 86: ...3 60 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Chapter 3 Installation ...
Страница 108: ...4 22 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Chapter 4 Turn Up and Test ...
Страница 130: ...B 12 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Appendix B Acceptance Test Plan ...
Страница 136: ...Index IN 6 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 ...