4-21
Cisco ONS 15200 Installation, Setup, and Test Manual
78-13765-01
Chapter 4 Turn Up and Test
Step 13
Clear all errors on test box and run the bit error rate test (BERT) error free for two hours. Complete Step
in
.
You have completed the span test for networks with no protection.
Procedure: Test the Bit Error Rate for Protected Channels
Continue with the following steps to test the BER for protected channels.
Step 14
Test the A-side protected channels:
a.
Write down the switchmode of all protected CLIPs in
b.
Set the switchmode to forced_a for all protected CLIPs.
c.
Verify through the web browser that all of the protected channels are active on the A side.
d.
Clear all errors on the test set and run BERT error free for two hours. Complete Step
.
Step 15
Test the B-side protected channels:
a.
Set the switchmode to forced_b for all protected CLIPs.
b.
Verify through the web browser that all of the protected channels are active on the B side.
c.
Clear all errors on the test set and run BERT error free for two hours. Complete Step
.
Step 16
Reset the original switch mode settings recorded in
Note
It is important to perform this step.
Содержание ONS 15200 Series
Страница 26: ...2 6 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Chapter 2 Pre Installation Procedures ...
Страница 86: ...3 60 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Chapter 3 Installation ...
Страница 108: ...4 22 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Chapter 4 Turn Up and Test ...
Страница 130: ...B 12 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Appendix B Acceptance Test Plan ...
Страница 136: ...Index IN 6 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 ...