3-42
Cisco ONS 15200 Installation, Setup, and Test Manual
78-13765-01
Chapter 3 Installation
Procedure: Install the Network Adaptation Module in the ONS 15252 MCU
Cisco builds NAM modules per customer design specifications. If you plan to install multiple NAMs,
verify that the NAM splitter ratio (50/50, 90/10, 10/90, 100/0, or 0/100) matches the requirements of the
associated CLIP module.
Caution
In an ONS 15200 Release 1.0.1 shelf assembly, you must install the Release 1.0.1 NAM, identified
by the “NEBS-3 compliant” faceplate. Cisco does not recommend or support placing NAMs without
the “NEBS-3 compliant” faceplate into an Release 1.0.1 shelf. Equipment damage may result. For
more information about shelf versions, see
“Shelf Version Considerations” procedure on page 3-5
Note
You can install Release 1.0.1 NAMs (identified by the “NEBS-3 compliant” faceplate label) in either
a Release 1.0 or Release 1.0.1 shelf. See
“Shelf Version Considerations” procedure on page 3-5
Step 1
Align the NAM with the NAM slot immediately below a previously installed CLIP module.
Step 2
Carefully insert the NAM into the slot. Make sure that the NAM is properly inserted in the lower guide
rail located in the NAM slot, and that the NAM connector and the backplane connector mate correctly.
Caution
When you insert the NAM, ensure that the fiber cables and connector emerging from the NAM are
not pinched, which could damage the fibers.
Step 3
Use a slot or Phillips screwdriver to tighten the NAM retaining screw.
Step 4
Remove the dust plugs from the CLIP module.
Step 5
Remove the dust cap from one of the three NAM MU connectors (for a protected channel) or one of the
two NAM MU connectors (for an unprotected channel), as shown in
. Start with the fibers
connected to the receivers, labeled either A or B.
Step 6
Clean and inspect the MU connector.
Step 7
For a protected channel, connect the NAM fiber labeled A and B to the corresponding MU optical
adapters (also labeled A and B) on the associated CLIP module.
Step 8
Repeat Steps
for the other receiver.
Step 9
For an unprotected channel, connect the optical-fiber jumper cable labeled A to the A-side MU adapter
on the associated CLIP module.
Step 10
Connect the transmitter optical fiber to the DWDM transmitter MU adapter on the CLIP (labeled with a
down arrow). See
.
Note
The receive side of the duplex fiber connected to the HFM is labeled with the intended side of the
passive optical shelf. The transmit side of the fiber is labeled with the transmitted power percentage.
Содержание ONS 15200 Series
Страница 26: ...2 6 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Chapter 2 Pre Installation Procedures ...
Страница 86: ...3 60 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Chapter 3 Installation ...
Страница 108: ...4 22 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Chapter 4 Turn Up and Test ...
Страница 130: ...B 12 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 Appendix B Acceptance Test Plan ...
Страница 136: ...Index IN 6 Cisco ONS 15200 Installation Setup and Test Manual 78 13765 01 ...