4-8
Cisco ONS 15200 Installation, Setup, and Test Manual
78-13765-01
Chapter 4 Turn Up and Test
Figure 4-2
An OSA-to-LM connection
Procedure: Check DWDM Receivers and Client Transmit Levels
Use the following steps to check DWDM receivers and client transmit levels.
Step 5
Attenuate the DWDM transmit port:
a.
Attenuate the output port of the B-side LM of the MCU so that the optical power measured is within
the DWDM receiver specification for each wavelength.
The receiver operating range is -31 and -8 dBm, but the default warning thresholds of -28 and -10
should be used on all CLIP interfaces. As a rough guide, the power level for each channel should be
between -19 and -10 dBm on the LM IN port.
b.
Record the attenuated power level for each channel in
.
c.
Insert the attenuated fiber-optical cable into the B-side IN port (
).
d.
Repeat Steps
54911
Line Module
Connect output to OSA and record
data in the appropriate tables.