4-38
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
July 2010
Chapter 4 Error Messages
EID-5082
{0} does not support:
- Low-order circuits that have both {1}-protected and
{2}-protected spans and that cross a node that does not have
low-order cross-connect capability.
- High-order circuits that carry low-order circuits with the
parameters described above.
Refer to the error message text.
EID-5083
This circuit is not the same size as the existing circuit {0}.
This circuit has size {1} and the existing circuit has size {2}.
During an RPR circuit creation on an
ML-Series card, the new circuit size and the
existing circuit size must be the same.
EID-5084
The Trunk model could not be found.
{0}
The trunk specified is not found.
EID-5085
The maximum number of VLAN DB profiles is {0}.
Refer to the error message.
EID-5086
The circuit roll failed.
You cannot bridge and roll the selected circuit because it has a
monitor circuit.
Refer to the error message.
EID-6000
This platform does not support power monitoring thresholds.
Refer to the error message text.
EID-6001
One of the XC cards has failures or is missing.
Check whether all the cross-connect cards
are installed and working.
EID-6002
One of the XC cards is locked.
Unlock the cross-connect card.
EID-6003
The OSC termination could not be created.
This ring ID is already assigned.
Enter a new ID for the ring.
EID-6004
A system reset cannot be performed while a BLSR ring is
provisioned on the node.
Remove the MS-SPRing from the node and
continue with the reset procedure.
EID-6005
The timing references could not be assigned.
- Only two DS1 or BITS interfaces can be specified.
- DS1 interfaces cannot be retimed and used as a reference.
- BITS-2 is not supported on this platform.
Refer to the error message text.
EID-6006
The timing references could not be assigned.
- An NE reference can only be used if the timing mode is LINE.
- A BITS reference can only be used if the timing mode is not
LINE.
- A Line reference can only be used if the timing mode is not
EXTERNAL.
Refer to the error message text.
EID-6008
SF BER and SD BER are not provisionable on the protect line
of a protection group.
Refer to the error message text.
WID-6009
If autoadjust GFP buffers is disabled, GFP buffers available
must be set to an appropriate value based on the distance
between the circuit endpoints.
Refer to the warning message text.
WID-6010
If auto detection of credits is disabled, credits available must be
set to a value less than or equal to the number of receive credits
on the connected FC endpoint.
Refer to the warning message text.
Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
Description
Содержание Cisco ONS 15600 SDH
Страница 18: ...Contents xviii Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...
Страница 20: ...Figures xx Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...
Страница 30: ...xxx Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 About this Guide ...
Страница 256: ...3 8 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 Chapter 3 Transient Conditions 3 3 28 WKSWPR ...
Страница 306: ...4 50 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 Chapter 4 Error Messages ...
Страница 318: ...Index IN 12 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...