4-36
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
July 2010
Chapter 4 Error Messages
EID-5049
Provisionable patchcords created between gray OC-N trunk
ports and multiplexer/demultiplexer ports are not supported.
Refer to the error message text.
EID-5050
The element model could not be found.
{0}
The specified element model cannot be
located.
WID-5051
The port state cannot be indirectly transitioned because the port
aggregates OCHCC circuits: if the port state needs to be
changed, edit it directly through port provisioning.
Refer to the warning message text.
EID-5052
The operation is not valid for the connection type.
You might have selected the incorrect
switch.
EID-5053
The operation cannot be performed because the connection is
under test access.
Refer to the error message text.
EID-5054
The TL1 tunnel could not be opened. {0}
Refer to the error message text.
EID-5055
Some patchcords were not deleted. Patchcords cannot be
deleted if they are incomplete or support any circuits, or if the
nodes supporting them are not connected.
Refer to the error message text.
EID-5056
This PPC cannot be deleted because one or more circuits are
provisioned over it.
Remove the circuits provisioned over the
provisionable patchcord before trying to
delete it.
EID-5057
The addition of the last node has not yet finished.
Please wait before trying to add a new node.
Refer to the error message text.
EID-5058
An OCHNC upgrade is applicable only to bidirectional circuits. Refer to the error message text.
EID-5059
The OCHNC upgrade failed.
One or more communication failures occurred during the
operation.
CTC encountered a complete failure while
upgrading optical channel network
connection.
EID-5060
The OCHNC upgrade partially failed.
One or more communication failures occurred during the
operation.
Create the OCHCC manually.
CTC encountered a partial failure while
upgrading an optical channel network
connection.
EID-5061
The overhead circuit source and destination must reside on the
same shelf.
Refer to the error message text.
EID-5062
A four-fiber {0} cannot be created using three cards.
A four-fiber MS-SPRing needs four cards.
WID-5063
The profile "{0}" includes a change to the OPEN-SLOT alarm
severity.
This change is disallowed for the ONS 15600. "{1}" will
continue to use the OPEN-SLOT severity of MN that is
included in the default configuration.
Other changes from the "{2}" profile were successfully applied
to {3}".
Refer to the warning message text.
EID-5064
{0}
{1}
This indicates the status of SNCP
switching.
Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
Description
Содержание Cisco ONS 15600 SDH
Страница 18: ...Contents xviii Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...
Страница 20: ...Figures xx Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...
Страница 30: ...xxx Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 About this Guide ...
Страница 256: ...3 8 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 Chapter 3 Transient Conditions 3 3 28 WKSWPR ...
Страница 306: ...4 50 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 Chapter 4 Error Messages ...
Страница 318: ...Index IN 12 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...