Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
July 2010
Chapter 1 General Troubleshooting
1.1.1 Facility Loopbacks
Figure 1-1
Facility/Payload Loopback Process on an STM-N Port
Caution
Before performing a facility loopback on an STM-N port, be sure the ASAP card contains at least two
data communications channel (DCC) paths to the node where the card is installed. A second DCC
provides a nonlooped path to log into the node after the loopback is applied, enabling you to remove the
facility loopback. Issuing a second DCC is not necessary if you are directly connected to the
ONS 15600 SDH containing the loopbacked ASAP card.
1.1.1.2 Card Behavior
Loopbacks either terminate or bridge the loopback signal. When a port terminates a facility loopback
signal, the signal only loops back to the originating port and is not transmitted downstream. When a port
bridges a loopback signal, the signal loops back to the originating port and is also transmitted
downstream.
The loopback itself is listed in the Conditions window. For example, the window would list the
LPBKFACILITY condition for a tested port. (The Alarms window will show AS-MT, which means that
alarms are suppressed on the facility during loopback.) In Software Release 8.0, an option in node
defaults allows you to specify that loopback conditions be reported as alarms, even though the port or
circuit is Locked,maintenance.
In addition to the Conditions window listing, the following behaviors occur:
•
If an electrical or optical port is in the
Locked-enabled, disabled
service state, it injects an alarm
indication signal (AIS) upstream and downstream.
•
When an electrical or optical port is placed in the
Locked-enabled
,
maintenance
service state
before loopback testing, the port clears the AIS signal upstream and downstream unless there is a
service-affecting defect that would also cause an AIS signal to be injected. For more information
about placing ports into alternate states for testing, refer to the “Change Card Settings” chapter of
the
Cisco ONS 15600 SDH Procedure Guide.
Caution
A lockout of protection must be executed before putting a two-fiber or four-fiber MS-SP Ring span into
a facility loopback state. That is, a span lockout of one side (such as the east side) of a two-fiber MS-SP
Ring is required before operating a facility loopback on the same (east) side of the ring. A span lockout
of one protection side (such as the east protection side) of a four-fiber MS-SP Ring is required before
operating a facility loopback on the same (east) side working line of the ring. If you do not execute the
lockout prior to creating the loopback, the ring can become stuck in an anomalous state after you release
the loopback.
STM-Nx
STM-Ny
SSXC
Test Set
x1
159639
Содержание Cisco ONS 15600 SDH
Страница 18: ...Contents xviii Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...
Страница 20: ...Figures xx Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...
Страница 30: ...xxx Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 About this Guide ...
Страница 256: ...3 8 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 Chapter 3 Transient Conditions 3 3 28 WKSWPR ...
Страница 306: ...4 50 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 Chapter 4 Error Messages ...
Страница 318: ...Index IN 12 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...