2-8
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
July 2010
Chapter 2 Alarm Troubleshooting
2.4 Alarm List by Logical Object Type
2.4 Alarm List by Logical Object Type
lists all ONS 15600 SDH Software Release 8.0 alarms and logical objects as they are given in
the system alarm profile. The list entries are organized logical object name and then by alarm or
condition name. Each entry refers to an alarm description in this chapter. Where appropriate, the alarm
entries also contain troubleshooting procedures.
Note
In a mixed network containing different types of nodes (such as an ONS 15310-CL, ONS 15454 SDH,
and ONS 15600 SDH), the initially displayed alarm list in the Provisioning > Alarm Profiles > Alarm
Profile Editor tab lists all conditions that are applicable to all nodes in the network. However, when you
load the default severity profile from a node, only applicable alarms will display severity levels.
Nonapplicable alarms can display “use default” or “unset.”
Note
In some cases this list does not follow alphabetical order, but it does reflect the order shown in CTC.
PPM
Pluggable port module (PPM), or Small Form-factor Pluggable (SFP), for the ASAP
card.
PWR
The node’s power supply.
STMN
An STM-N line on an STM-N card.
VCMON-HP
High-order path virtual concatenation monitoring.
Note
The network element reports alarms or conditions on ingress ports of the
card. Alarms detected at the internal ports (TERM side) will be ingress
mapped to the MON side. The alarm profile entities of VCMON-HP, if
available, should be changed to the same severity as the customized severity
for a specific VCMON-HP alarm.
Table 2-7
Alarm Logical Object Type Definitions (continued)
Table 2-8
ONS 15600 SDH Alarm List by Logical Object in Alarm Profile
BITS: AIS (NR)
NE-SREF: FRCDSWTOTHIRD (NA)
STMN: FE-FRCDWKSWPR-SPAN (NA)
BITS: BPV (MN)
NE-SREF: FRNGSYNC (NA)
STMN: FE-LOCKOUTOFPR-ALL (NA)
BITS: LOF (MN)
NE-SREF: HLDOVRSYNC (NA)
STMN: FE-LOCKOUTOFPR-SPAN (NA)
BITS: LOS (MN)
NE-SREF: MANSWTOINT (NA)
STMN: FE-MANWKSWBK-SPAN (NA)
BITS: SSM-DUS (NA)
NE-SREF: MANSWTOPRI (NA)
STMN: FE-MANWKSWPR-RING (NA)
BITS: SSM-FAIL (MN)
NE-SREF: MANSWTOSEC (NA)
STMN: FE-MANWKSWPR-SPAN (NA)
BITS: SSM-LNC (NA)
NE-SREF: MANSWTOTHIRD (NA)
STMN: FE-SF-SPAN (NA)
BITS: SSM-OFF (NA)
NE-SREF: SSM-LNC (NA)
STMN: FEPRLF (MN)
BITS: SSM-PRC (NA)
NE-SREF: SSM-PRC (NA)
STMN: FORCED-REQ-RING (NA)
BITS: SSM-SDH-TN (NA)
NE-SREF: SSM-SDH-TN (NA)
STMN: FORCED-REQ-SPAN (NA)
BITS: SSM-SETS (NA)
NE-SREF: SSM-SETS (NA)
STMN: FULLPASSTHR-BI (NA)
BITS: SSM-SMC (NA)
NE-SREF: SSM-SMC (NA)
STMN: HELLO (MN)
Содержание Cisco ONS 15600 SDH
Страница 18: ...Contents xviii Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...
Страница 20: ...Figures xx Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...
Страница 30: ...xxx Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 About this Guide ...
Страница 256: ...3 8 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 Chapter 3 Transient Conditions 3 3 28 WKSWPR ...
Страница 306: ...4 50 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 Chapter 4 Error Messages ...
Страница 318: ...Index IN 12 Cisco ONS 15600 SDH Troubleshooting Guide R8 0 July 2010 ...