A-28
Cisco 7600 Series Router Cisco IOS Software Configuration Guide, Release 12.2SX
OL-4266-08
Appendix A Online Diagnostic Tests
Exhaustive Memory Tests
TestFabricCh0Health
The TestFabricCh0Health test constantly monitors the health of the ingress and egress data paths for
fabric channel 0 on 10-gigabit modules. The test runs every five seconds. Ten consecutive failures are
treated as fatal and the module resets; three consecutive reset cycles may result in a fabric switchover.
TestFabricCh1Health
The TestFabricCh1Health test constantly monitors the health of the ingress and egress data paths for
fabric channel 1 on 10-gigabit modules. The test runs every five seconds. Ten consecutive failures are
treated as fatal and the module resets; three consecutive reset cycles may result in a fabric switchover.
Exhaustive Memory Tests
The exhaustive memory tests include the following tests:
TestFibTcamSSRAM, page A-29
TestAsicMemory, page A-29
TestAclQosTcam, page A-30
TestNetflowTcam, page A-30
Table A-49
TestFabricSCh0Health Test Attributes
Attribute
Description
Disruptive/Nondisruptive
Nondisruptive.
Recommendation
Do not turn this test off. Use as a health-monitoring test.
Default
On.
Release
12.1(13)E, 12.2(14)SX.
Corrective action
The module resets after 10 consecutive failures. Three
consecutive resets powers down the module.
Hardware support
WS-X6704-10GE and WS-6702-10GE.
Table A-50
TestFabricCh1Health Test Attributes
Attribute
Description
Disruptive/Nondisruptive
Nondisruptive.
Recommendation
Do not turn this test off. Use as a health-monitoring test.
Default
On.
Release
12.1(13)E, 12.2(14)SX.
Corrective action
The module resets after 10 consecutive failures. Three
consecutive failures resets powers down the module.
Hardware support
WS-X6704-10GE module.