A-3
Cisco 7600 Series Router Cisco IOS Software Configuration Guide, Release 12.2SX
OL-4266-08
Appendix A Online Diagnostic Tests
Per-Port Tests
TestMacNotification
The TestMacNotification test verifies that the data and control path between DFC modules and
supervisor engines is working properly. This test also ensures Layer 2 MAC address consistency across
Layer 2 MAC address tables. The test runs every six seconds. Ten consecutive failures causes the module
to reset during bootup or runtime (default). After three consecutive resets, the module powers down.
Per-Port Tests
The per-port tests consist of the following tests:
TestNonDisruptiveLoopback, page A-4
TestLoopback, page A-4
TestActiveToStandbyLoopback, page A-5
TestTransceiverIntegrity, page A-5
TestNetflowInlineRewrite, page A-5
Table A-2
TestScratchRegister Test Attributes
Attribute
Description
Disruptive/Nondisruptive
Nondisruptive.
Recommendation
Do not disable.
Default
On.
Release
12.2(14)SX.
Corrective action
Reset the malfunctioning supervisor engine or power down
the module.
Hardware support
Supervisor Engine 720, DFC-equipped modules,
WS-X6148-FE-SFP, WS-X6148A-GE-TX, and
WS-X6148A-RJ-45
.
Table A-3
TestMacNotification Test Attributes
Attribute
Description
Disruptive/Nondisruptive
Nondisruptive.
Recommendation
Do not disable.
Default
On.
Release
12.2(14)SX.
Corrective action
Reset the module. After the module has ten consecutive
failures or three consecutive resets, it powers down.
Hardware support
DFC-equipped modules.