LAMP ON:
1. With the projection head and ballast connected to each other, and with the
ballast breaker on, press
Menu
. The
LCD STATUS DISPLAY
at the rear of the
projector will show a “Lamp Size” of 2000, 3000, 4500 or 6000 watts,
depending on its last setting. Factory default=6000. Use
or
to select
the lamp that is currently installed. This should also appear on the Lamp
Installed label located on the lamp door. NOTE: A lamp password is required
to change lamp type/size, unless the “Enable Password” service option has
been turned off.
2. Turn on the projection head and lamp by pressing
POWER on any of the
projector’s keypads.
3. For subsequent power-ups of this lamp, press
POWER. There is no need
to reset the lamp size until a different-sized lamp is installed.
LAMP OFF:
1. Press
(POWER) on any of the projector’s keypads.
2.
WAIT
for fans to continue running for 10 minutes to cool the lamp.
3. Proceed with full shutdown of the system, if desired.
If the lamp fails to ignite, the projector will automatically re-try ignition using 100%
of the maximum power acceptable for the lamp. If this re-try also fails, and there is
no error code indicating a specific problem such as an open lamp door or an over-
temperature condition, the lamp size may be incorrectly defined. For instance, the
defined “Lamp Size” may be 2 kW when a 6 kW lamp is present. To check the
“Lamp Size” setting, press
Menu
while the lamp is off. The
LCD STATUS DISPLAY
at
the rear of the projector will show a “Lamp Size” of 2000, 3000, 4500 or 6000 watts,
depending on its most recent setting (factory default=6000). Enter password (unless it
has been turned off) and select the lamp that is currently installed. If the lamp still
will not ignite, a qualified service technician should check all lamp connections and,
if OK, replace the lamp.
See also Section 5, Troubleshooting section.
Whenever you install a new lamp in the
projector, access the Lamp menu to record
the lamp serial number in the projector’s
memory. You can also choose a lamp mode
for regulating power and light output,
optimize lamp performance, and access
other read-only information pertaining to
past and present lamps.
LAMP HOURS
shows the number of hours
logged on the current lamp. Whenever you
record a new lamp serial number, this value
automatically resets to “0”, where it begins
to log time for the new lamp. NOTE: Read-
only. This information also appears in the Status menu.
LAMP S/N
is the serial number recorded for the current lamp. When you install a new
lamp and enter its serial number, the number will appear here. NOTE: Read-only.
Turning the Lamp on/off
'
If the Lamp Won’t Turn On
'
Lamp Menu
'
Содержание Roadie 25K
Страница 6: ......
Страница 15: ...INSTALLATION AND SETUP Roadie 25K User s Manual 2 9 Figure 2 10 Switching Between Flat Scope Displays ...
Страница 56: ......
Страница 153: ...SPECIFICATIONS Roadie 25K User s Manual 6 7 ...
Страница 164: ......
Страница 165: ...Appendix B Remote Keypad Roadie 25K User s Manual B 1 Figure B 1 Standard Remote Keypad ...
Страница 166: ......
Страница 168: ...SERIAL COMMUNICATION CABLES C 2 Roadie 25K User s Manual ...
Страница 169: ...SERIAL COMMUNICATION CABLES Roadie 25K User s Manual C 3 ...
Страница 170: ......
Страница 186: ......