Connecting Two Quantum Maestro Orchestrators for Redundancy
Quantum Maestro Getting Started Guide | 90
Item
Description
14
Client you can use to configure the Gaia Operating System on the Security Appliances in
Security Groups.
You connect:
n
Over SSH to the command line (Gaia Clish) of Security Groups.
n
With a web browser to the Gaia Portal of Security Groups.
15
First Quantum Maestro Orchestrator:
n
Connects Network 1 and Network 2 to the Security Appliances (
26
,
27
,
29
, and
30
).
n
Distributes the traffic between the Security Appliances in the Security Groups.
16
Second Quantum Maestro Orchestrator:
n
Connects Network 1 and Network 2 to the Security Appliances (
26
,
27
,
29
, and
30
).
n
Distributes the traffic between the Security Appliances in the Security Groups.
17
A DAC that connects the dedicated Synchronization ports on the Quantum Maestro
Orchestrators (
15
and
16
).
Important:
n
This connection is only used to synchronize the configuration of Security
Groups between the Quantum Maestro Orchestrators.
n
MHO-175 and MHO-170 require a 100 GbE DAC or 40 GbE DAC cable.
n
MHO-140 requires a 10 GbE DAC cable.
18
A DAC cable, Fiber cable (with transceivers), or Breakout cable that connects a Downlink port
on the
first
Quantum Maestro Orchestrator (
15
) to the Security Appliance (
30
).
19
A DAC cable, Fiber cable (with transceivers), or Breakout cable that connects a Downlink port
on the
second
Quantum Maestro Orchestrator (
16
) to the Security Appliance (
30
).
20
A DAC cable, Fiber cable (with transceivers), or Breakout cable that connects a Downlink port
on the
first
Quantum Maestro Orchestrator (
15
) to the Security Appliance (
29
).
21
A DAC cable, Fiber cable (with transceivers), or Breakout cable that connects a Downlink port
on the
second
Quantum Maestro Orchestrator (
16
) to the Security Appliance (
29
).
22
A DAC cable, Fiber cable (with transceivers), or Breakout cable that connects a Downlink port
on the
first
Quantum Maestro Orchestrator (
15
) to the Security Appliance (
27
).
23
A DAC cable, Fiber cable (with transceivers), or Breakout cable that connects a Downlink port
on the
second
Quantum Maestro Orchestrator (
16
) to the Security Appliance (
27
).
24
A DAC cable, Fiber cable (with transceivers), or Breakout cable that connects a Downlink port
on the
first
Quantum Maestro Orchestrator (
15
) to the Security Appliance (
26
).
25
A DAC cable, Fiber cable (with transceivers), or Breakout cable that connects a Downlink port
on the
second
Quantum Maestro Orchestrator (
16
) to the Security Appliance (
26
).
26
Security Appliance 2 in the Security Group 2 (
28
).
27
Security Appliance 1 in the Security Group 2 (
28
).
Table: Explanations (continued)