Dual Site with Direct Connection
Quantum Maestro Getting Started Guide | 132
Dual Site with Direct Connection
Diagram
This example is for MHO-140.
Description
1. On each site, two Quantum Maestro Orchestrators are connected for redundancy:
n
On each site, Port 48 on Quantum Maestro Orchestrators is for the internal synchronization.
n
On each site, Port 47 on Quantum Maestro Orchestrators is for the external synchronization
between sites.
n
On each site, each Security Appliance has an Expansion Line Card.
Downlink ports on different Quantum Maestro Orchestrators connect to odd and to even
ports on the Expansion Line Card.
2. The first Orchestrator on the first site (Orchestrator ID 1_1) connects directly to the first
Orchestrator on the second site (Orchestrator ID 2_1).
3. The second Orchestrator on the first site (Orchestrator ID 1_2) connects directly to the second
Orchestrator on the second site (Orchestrator ID 2_2).
Diagram
Содержание QUANTUM MAESTRO
Страница 1: ... Classification Protected 11 November 2021 QUANTUM MAESTRO Getting Started Guide ...
Страница 88: ...Connecting Two Quantum Maestro Orchestrators for Redundancy Quantum Maestro Getting Started Guide 88 Example ...
Страница 159: ...Dual Site with four Switches Quantum Maestro Getting Started Guide 159 Diagram ...