Dual Site with four Switches
Quantum Maestro Getting Started Guide | 160
Explanations
Item
Description
1
A port on the
first
Layer 2 switch (5) on the
first
site that connects to a corresponding port
(2) on the
first
Layer 2 switch (6) on the
second
site.
2
A port on the
first
Layer 2 switch (6) on the
second
site that connects to a corresponding
port (1) on the
first
Layer 2 switch (5) on the
first
site.
3
A port on the
first
Layer 2 switch (5) on the
first
site that connects to the dedicated external
synchronization port (14) on the
first
Quantum Maestro Orchestrator (
15
) on the
first
site.
4
A port on the
first
Layer 2 switch (6) on the
second
site that connects to the dedicated
external synchronization port (17) on the
first
Quantum Maestro Orchestrator (
18
) on the
second
site.
5
The
first
Layer 2 switch on the
first
site.
6
The
first
Layer 2 switch on the
second
site.
7
A port on the
second
Layer 2 switch (11) on the
first
site that connects to the dedicated
external synchronization port (22) on the
second
Quantum Maestro Orchestrator (
23
) on
the
first
site.
8
A port on the
second
Layer 2 switch (11) on the
first
site that connects to a corresponding
port (10) on the
second
Layer 2 switch (12) on the
second
site.
9
A port on the
second
Layer 2 switch (12) on the
second
site that connects to the dedicated
external synchronization port (25) on the
second
Quantum Maestro Orchestrator (
26
) on
the
second
site.
10
A port on the
second
Layer 2 switch (12) on the
second
site that connects to a
corresponding port (8) on the
second
Layer 2 switch (11) on the
first
site.
11
The
second
Layer 2 switch on the
first
site.
12
The
second
Layer 2 switch on the
second
site.
13
DAC cables, Fiber cables (with transceivers), or Breakout cables that connect Downlink
ports on the
first
Quantum Maestro Orchestrator (
11
) on the
first
site to the Security
Appliance (
29
,
31
and
34
) on the
first
site.
These cables connect to the
odd
port of an Expansion Line Card on Security Appliances.
14
The dedicated external synchronization port (Port 47) on the
first
Quantum Maestro
Orchestrator (
15
) on the
first
site.
This port connects with a DAC cable or Fiber cable (with transceivers) to the
first
Layer 2
switch (5 to port 3) on the
first
site.
15
The
first
Quantum Maestro Orchestrator on the
first
site.
Table: Explanations