92001i-DF-EU - 1900W RATED DUAL FUEL INvERTER GENERATOR
OPERATION
18
Surge Protection
Electronic devices, including computers and many programmable
appliances use components that are designed to operate within a
narrow voltage range and may be affected by momentary voltage
fluctuations. While there is no way to prevent voltage fluctuations,
you can take steps to protect sensitive electronic equipment.
–
Install UL1449, CSA-listed, plug-in surge suppressors on the
outlets feeding your sensitive equipment.
Surge suppressors come in single- or multi-outlet styles.
They’re designed to protect against virtually all short-duration
voltage fluctuations.
Starting the Engine: Petrol
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator. Never start
or stop the generator with electrical devices plugged in or
turned on.
3. Turn the fuel vent lever to the “ON” position.
Cold Engine Start
4. Move the dial to the “CHOKE” position.
5. Pull the recoil cord slowly until resistance is felt and then pull
rapidly.
6. As the engine warms up, turn the dial to the petrol “RUN”
position.
Warm Engine Start
7. Turn the dial to the petrol “RUN” position.
8. Pull the recoil cord slowly until resistance is felt and then pull
rapidly.
Содержание 92001i-DF-EU
Страница 200: ...92001i DF EU 1900W RATED Dual Fuel Inverter Generator Parts Diagram 200 PARTS DIAGRAM...
Страница 203: ...92001i DF EU 1900W RATED Dual Fuel Inverter Generator Parts Diagram 203 Engine Parts Diagram...
Страница 205: ...92001i DF EU 1900W RATED Dual Fuel Inverter Generator Parts Diagram 205 Wiring Diagram...