92001i-DF-EU - 1900W RATED DUAL FUEL INvERTER GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
6
–
Petrol expands or contracts with ambient temperatures. Never
fill the petrol tank to full capacity, as petrol needs room to
expand if temperatures rise.
LPG:
–
LPG is highly flammable and explosive.
–
LPG is under pressure and can cause a fire or explosion if
ignited.
–
LPG is heavier than air and can settle in low places while
dissipating.
–
LPG has a distinctive odor added to help detect potential leaks
quickly.
–
In any petroleum gas fire, flames should not be extinguished
unless the fuel supply valve is turned OFF. This is because if a
fire is extinguished and a supply of fuel is not turned OFF, then
an explosion hazard could be created.
–
When exchanging LPG cylinders, be sure the cylinder valve is
of the same type.
–
Always keep the LPG cylinder in an upright position.
–
LPG will burn skin if it comes in contact with it. Keep any and
all LPG away from skin at all times.
When adding or removing petrol:
DO NOT light or smoke cigarettes near the generator.
Turn the generator off and let it cool for at least ten minutes before
removing the petrol cap. Loosen the cap slowly to relieve pressure
in the tank.
Only fill or drain petrol outdoors in a well-ventilated area.
DO NOT pump petrol directly into the generator at the gas station.
Use an approved container to transfer the fuel to the generator.
DO NOT overfill the petrol tank.
DO NOT try to add fuel whilst the engine is hot or running.
Always keep petrol away from sparks, open flames, pilot lights,
heat and other sources of ignition.
When starting the generator:
DO NOT attempt to start a damaged generator.
Make certain that the petrol cap, air filter, spark plug, fuel lines
and exhaust system are properly in place.
Allow spilled petrol to evaporate fully before attempting to start
the engine.
Make certain that the generator is resting firmly on level ground.
When operating the generator:
DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.
DO NOT try to add fuel whilst the engine is hot or running.
When transporting or servicing the generator:
Make certain that the fuel valve is in the OFF position and the
petrol tank is empty.
For LPG compatible models, be sure that the LPG cylinder is
disconnected and stored securely away from the generator.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights, heat and other
sources of ignition.
Do not store generator, petrol or LPG cylinders near furnaces,
water heaters, or any other appliances that produce heat or have
automatic ignitions.
WARNING
Never use a petrol container, petrol tank, LPG connector hose,
LPG cylinder or any other fuel item that is broken, cut, torn or