92001i-DF-EU - 1900W RATED DUAL FUEL INvERTER GENERATOR
STORAGE
26
STORAGE
DANGER
Petrol vapors are highly flammable and extremely explosive.
DO NOT light or smoke cigarettes. Fire or explosion can cause
severe burns or death.
Only fill or drain fuel outdoors in a well-ventilated area. DO
NOT pump petrol directly into the generator. Use an approved
container to transfer the fuel to the generator.
Never use a petrol container, petrol tank, or any other fuel
item that is broken, cut, torn or damaged.
DO NOT overfill the petrol tank. Always keep fuel away from
sparks, open flames, pilot lights, heat and other sources of
ignition.
Short Term Storage (up to 30 days)
Petrol in the petrol tank has a maximum shelf life of up to 1 year
with the addition of properly formulated fuel stabilizers and if
stored in a cool, dry place. Petrol in the carburetor, however, may
gum up and clog the carburetor if it isn’t used or drained within
2-4 weeks. We recommend always removing fuel when not in use
for 30 days.
If using the generator within 2 weeks, follow the steps according
to
Stopping the Engine
section.
1. If not using the generator for 2-4 weeks, begin by making
sure all appliances are disconnected from the generator.
2. Start the generator as instructed in
Starting the Engine
section.
3. Let the engine run until fuel starvation has stopped the
engine.
4. After the engine stops, turn the dial counterclockwise to the
“STOP” position.
Mid Term Storage (30 days – 1 year)
Petrol in the tank has a maximum shelf life of up to 1 year with
the addition of a properly formulated fuel stabilizer and stored in a
cool, dry place.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the petrol tank.
3. Start engine by following directions in the
Starting the Engine
section.
4. Run the generator for 10 minutes so the treated petrol cycles
through the fuel system and carburetor.
5. Let the engine run until fuel starvation has stopped the
engine.
6. After the engine stops, turn the dial counterclockwise to the
“STOP” position.
7. After fuel has run out and the engine has stopped, allow the
engine to cool.
8. Remove maintenance cover.
9. Remove the spark plug and pour about a tablespoon of oil into
the cylinder.
10. SLOWLY pull the recoil to rotate the engine to distribute and
lubricate the cylinder.
11. Re-install the spark plug and spark plug wire.
12. Re-install the maintenance cover.
13. Clean the generator according to
Cleaning the Generator
.
14. Store the generator in a cool, dry place out of direct sunlight.
Long Term Storage (more than 1 year)
For storage over 1 year, the petrol tank and carburetor must be
completely drained of petrol.
1. Be sure all appliances are disconnected from generator.
2. Place inverter on blocks to allow appropriate petrol container
or pan to slide under inverter.
3. Remove the maintenance cover.
4. Turn the dial to the petrol “RUN” position.
5. Using a Phillips screwdriver, rotate drain screw
counterclockwise (3) full turns. Petrol will drain through clear
tubing out underneath the inverter. Make sure draining petrol
empties into an appropriate container.
6. When petrol stops flowing from the clear tube, rotate drain
screw clockwise until tight. Properly dispose of the drained
petrol according to local regulations or guidelines.
7. Turn the fuel dial to the “STOP” position.
8. Follow steps 8-12 according to Short Term Storage.