14-6
August 2003
Access Navigator - Release 1.8
Alarm Clearing
Clear Alarms – FDL
EOC
Primary/Secondary
Link Down
EOC LAPD data link
communication not established
with the switch. Access Navigator
periodically retries to establish
LAPD data link with the switch.
Ensure DS1 assigned to EOC is
healthy.
Note: This alarm will also occur if
TMC or EOC is set to none.
Check status of DS1 assigned for
EOC with the following
command:
status eoc
Check EOC provisioning with the
following command:
show eoc
Use following command to change
setting:
set eoc
<
primary
/
secondary>
ds1
<n>
Manually set minor
alarm
Allows user to set and clear
critical alarm state. LED, relay,
alarm, and event logs follow
setting.
Use following command to clear
alarm:
set alarms minor off
On Board Power Supply
A/B
Failure
DC power supply on the controller
(A or B) caused a failure.
Reporting controller card (A or B)
must be replaced.
Remote Device #
n:
T1
#
x
Loss of Carrier
Remote device on DS1 #
n
reported loss of carrier on T1 #
x
.
Clear trouble at remote device.
Remote Device #
n:
T1
#
x
Loss of Synch
Remote device on DS1 #
n
reported loss of synchronization
on T1 #
x
.
Clear trouble at remote device.
Remote Device #
n:
T1
#
x
rx AIS
Remote device on DS1 #
n
received Blue alarm (AIS) on T1
#
x
.
Clear trouble at remote device.
Remote Device #
n:
T1
#
x
rx Yellow alarm
Remote device on DS1 #
n
received Yellow alarm (RAI) on
T1 #
x
.
Clear trouble at remote device.
Remote Device #
n
: V.35
loss of RTS
Remote device on DS1 #
n
reported loss of RTS on V.35
interface.
Clear trouble at remote device.
Table 14-3 CLI Minor Alarm Message and Trouble Clearing Procedure
Event Message
Description
Trouble Clearing Procedure
Содержание Access Navigator
Страница 1: ...Access Navigator USER MANUAL Part Number 770 0079 AP Product Release 1 8 August 2003 ...
Страница 82: ...4 18 August 2003 Access Navigator Release 1 8 Access Navigator GR 303 Host with P Phone Ordering Information ...
Страница 104: ...5 22 August 2003 Access Navigator Release 1 8 Physical Installation Attach Access Navigator to Plywood ...
Страница 170: ...6 66 August 2003 Access Navigator Release 1 8 Electrical Installation Exit Management Session ...
Страница 182: ...7 12 August 2003 Access Navigator Release 1 8 Start Management Session NetworkValet EMS and Valet Management ...
Страница 214: ...9 20 August 2003 Access Navigator Release 1 8 Provision DCS Service Test DS1 and DS0 Circuits ...
Страница 296: ...12 18 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via FDL Test DS1 and DS0 Circuits ...
Страница 320: ...13 24 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via IP DS0 Test DS1 and DS0 Circuits ...
Страница 342: ...14 22 August 2003 Access Navigator Release 1 8 Alarm Clearing Ethernet Link Status LED ...
Страница 434: ...16 36 August 2003 Access Navigator Release 1 8 Maintenance Procedures Install SIMM on Controller Card ...
Страница 456: ...17 22 August 2003 Access Navigator Release 1 8 Update Controller Card Software Download Software ...
Страница 634: ...18 178 August 2003 Access Navigator Release 1 8 CLI Language Reference CLI Command List ...
Страница 658: ...B 6 August 2003 Access Navigator Release 1 8 FDL Interface Access Bank II Capabilities ...
Страница 668: ...C 10 August 2003 Access Navigator Release 1 8 SNMP Interface SNMP Trap Reports ...
Страница 682: ...GlossaryGlossaryGlossaryGlossary 14 August 2003 Access Navigator Release 1 8 Glossary ...
Страница 704: ...Index 1 22 August 2003 Access Navigator Release 1 8 Index ...