Alarm Clearing
Clear Alarms – FDL
Table 14-3 CLI Minor Alarm Message and Trouble Clearing Procedure
Event Message
Description
Trouble Clearing Procedure
-48V DC power
A/B
Low or Missing
-48V DC power supply to the
controller (A or B) is low or
missing. Under normal condition
power is shared between controller
cards.
Check power cable connection or
battery voltage of the reporting
controller card.
Alarm Input
1/2/3
Detected
Contact closure was detected on
the indicated alarm input (1,2, or
3). Alarm inputs can be wired to
the facility alarm system. Under
normal conditions the facility
alarm system should provide open
contacts to the alarm inputs.
Providing contact closure to an
alarm input results in this alarm.
The alarm is cleared when the
contact is opened.
Controller
A/B
Incompatible
Controllers do not support the
same functionality; for example,
one supports EOC/TMC and the
other does not.
Remove the standby controller and
replace with a compatible
controller (see
Replace Controller
Card
on
page 16-3
or update
controller with compatible
software (see
Update Controller
Card Software
on
page 17-1
).
Controller
A/B
Removed
Upon removal the controller card
(A or B), the remaining controller
card is now
active
.
Insert a good controller card into
the empty slot
Controller A/B software
version mismatch
Controller card software versions
do not match.
Update offending controller with
appropriate software (see
Update
Controller Card Software
on
page 17-1
).
DS1
n
Major Line CV
DS1 is receiving Line Code
Violations at a rate greater than
1.0 x 10-3. This indicates a weak
signal or faulty wiring.
Correct the problem with the
incoming DS1 signal, or use
following command to provision
the DS1 as out of service:
set ds1
<n> <up|down>
Содержание Access Navigator
Страница 1: ...Access Navigator USER MANUAL Part Number 770 0079 AP Product Release 1 8 August 2003 ...
Страница 82: ...4 18 August 2003 Access Navigator Release 1 8 Access Navigator GR 303 Host with P Phone Ordering Information ...
Страница 104: ...5 22 August 2003 Access Navigator Release 1 8 Physical Installation Attach Access Navigator to Plywood ...
Страница 170: ...6 66 August 2003 Access Navigator Release 1 8 Electrical Installation Exit Management Session ...
Страница 182: ...7 12 August 2003 Access Navigator Release 1 8 Start Management Session NetworkValet EMS and Valet Management ...
Страница 214: ...9 20 August 2003 Access Navigator Release 1 8 Provision DCS Service Test DS1 and DS0 Circuits ...
Страница 296: ...12 18 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via FDL Test DS1 and DS0 Circuits ...
Страница 320: ...13 24 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via IP DS0 Test DS1 and DS0 Circuits ...
Страница 342: ...14 22 August 2003 Access Navigator Release 1 8 Alarm Clearing Ethernet Link Status LED ...
Страница 434: ...16 36 August 2003 Access Navigator Release 1 8 Maintenance Procedures Install SIMM on Controller Card ...
Страница 456: ...17 22 August 2003 Access Navigator Release 1 8 Update Controller Card Software Download Software ...
Страница 634: ...18 178 August 2003 Access Navigator Release 1 8 CLI Language Reference CLI Command List ...
Страница 658: ...B 6 August 2003 Access Navigator Release 1 8 FDL Interface Access Bank II Capabilities ...
Страница 668: ...C 10 August 2003 Access Navigator Release 1 8 SNMP Interface SNMP Trap Reports ...
Страница 682: ...GlossaryGlossaryGlossaryGlossary 14 August 2003 Access Navigator Release 1 8 Glossary ...
Страница 704: ...Index 1 22 August 2003 Access Navigator Release 1 8 Index ...