Access Navigator - Release 1.8
August 2003
15-43
Diagnostics & Troubleshooting
Bit Patterns and Error Tests
Bit Patterns and Error Tests
NOTE:
The DS1 must be set Out of Service, using the
set
ds1
<n>
down
command,
before you can use loopbacks or test patterns.
NOTE:
Use the
send
ds1
<n>
off
command to turn off loopbacks and patterns.
NOTE:
Sending an unframed pattern will cause a DS1 Loss of Frame (LOF).
NOTE:
Put the remote CSU or NIU in line loopback mode before using this command for
BER testing. (See
DS1 CSU Loopup
and
DS1 Network Loopup
.)
NOTE:
The internal Bit Error Rate Testers (BERTs) are always monitoring the DS1 inputs.
Anytime a BER test pattern is present, whether internally or externally generated, the BER for
the last one-second interval can be displayed using the
status
ds1
command (see
Status
DS1
on
page 15-13
). Bit errors are also recorded in the BERT log (see
BERT Log
on
page 15-7
).
n
Send DS1 (Pattern) Off
... 15-43
n
Send DS1 Line Pattern
... 15-43
n
Send DS1 Payload Pattern
... 15-44
n
Send DS1 Line Pattern with BER Test
... 15-46
n
Send DS1 Payload Pattern with BER Test
... 15-49
Send DS1 (Pattern) Off
This command stops (turns off) all
qrss
and
prbs
test patterns sent from the Access Navigator. The
system default is off.
Syntax:
send ds1 <n> off
Send DS1 Line Pattern
This command transmits an unframed test pattern to verify the quality of the DS1 signal reaching far-
end CSU equipment, such as the Access Bank II. The operator can select from several Pseudo Random
Bit Sequence (PRBS) and Quasi Random Signal Source (QRSS) patterns.
When the operator commands the selected pattern, the Access Navigator generates and transmits the
unframed pattern over the DS1. See Figure 15-23. Sending an unframed pattern will cause a DS1 Loss
of Frame (LOF) on both the Access Navigator and the remote CSU.
An external Bit Error Rate Tester (BERT) can be located anywhere on the network or at the customer
premises as shown in the figure.
When testing is complete, the
send
ds1
off
command must be used to turn off the test pattern.
Содержание Access Navigator
Страница 1: ...Access Navigator USER MANUAL Part Number 770 0079 AP Product Release 1 8 August 2003 ...
Страница 82: ...4 18 August 2003 Access Navigator Release 1 8 Access Navigator GR 303 Host with P Phone Ordering Information ...
Страница 104: ...5 22 August 2003 Access Navigator Release 1 8 Physical Installation Attach Access Navigator to Plywood ...
Страница 170: ...6 66 August 2003 Access Navigator Release 1 8 Electrical Installation Exit Management Session ...
Страница 182: ...7 12 August 2003 Access Navigator Release 1 8 Start Management Session NetworkValet EMS and Valet Management ...
Страница 214: ...9 20 August 2003 Access Navigator Release 1 8 Provision DCS Service Test DS1 and DS0 Circuits ...
Страница 296: ...12 18 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via FDL Test DS1 and DS0 Circuits ...
Страница 320: ...13 24 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via IP DS0 Test DS1 and DS0 Circuits ...
Страница 342: ...14 22 August 2003 Access Navigator Release 1 8 Alarm Clearing Ethernet Link Status LED ...
Страница 434: ...16 36 August 2003 Access Navigator Release 1 8 Maintenance Procedures Install SIMM on Controller Card ...
Страница 456: ...17 22 August 2003 Access Navigator Release 1 8 Update Controller Card Software Download Software ...
Страница 634: ...18 178 August 2003 Access Navigator Release 1 8 CLI Language Reference CLI Command List ...
Страница 658: ...B 6 August 2003 Access Navigator Release 1 8 FDL Interface Access Bank II Capabilities ...
Страница 668: ...C 10 August 2003 Access Navigator Release 1 8 SNMP Interface SNMP Trap Reports ...
Страница 682: ...GlossaryGlossaryGlossaryGlossary 14 August 2003 Access Navigator Release 1 8 Glossary ...
Страница 704: ...Index 1 22 August 2003 Access Navigator Release 1 8 Index ...