Access Navigator - Release 1.8
August 2003
16-21
Maintenance
Procedures
Replace Quad T1 Framer Card
Verify Equipment Status
1. Start management session, if not already logged on.
2. Display clock source assignments by entering the following command:
show clock
A message similar to the following will appear.
Primary Master Transmit Clock Source: DS1 12
Secondary Master Transmit Clock Source: INTERNAL
3. Set all four DS1 circuits on QF card out of service to prevent alarms with the following command,
where
<n>
is a range of four DS1 numbers such as 9-12:
set ds1 <n> down
Example:
set ds1 9-12 down
4. If no DS1s are used as a primary or secondary clock source on the Quad T1 Framer card to be
removed, skip to
Remove Front Cover
on
page 16-22
.
Temporarily Move Clock Sources (if required)
1. Record original clock source assignments so they can be restored later.
NOTE:
In the following two steps, the temporary clock source should be of equal or
higher Stratum clock level, such as from a central office switch. In Access Navigators with
the GR-303 option, the
status
ds1
all
command will list the status of “switch” type DS1s
as “In Service.”
2. Move primary clock source (if any) to a DS1 on a different QF card with the following command,
where
<n>
is the DS1 number:
set clock1 ds1 <n>
Example:
set clock1 ds1 25
3. Move secondary clock source (if any) to a DS1 on a different QF card with the following command,
where
<n>
is the DS1 number:
set clock2 ds1 <n>
Example:
set clock2 ds1 29
4. Verify clock source settings with the following command, where
<n>
is the DS1 number:
show clock
A message similar to the following will appear.
Primary Master Transmit Clock Source: DS1 12
Secondary Master Transmit Clock Source: INTERNAL
Содержание Access Navigator
Страница 1: ...Access Navigator USER MANUAL Part Number 770 0079 AP Product Release 1 8 August 2003 ...
Страница 82: ...4 18 August 2003 Access Navigator Release 1 8 Access Navigator GR 303 Host with P Phone Ordering Information ...
Страница 104: ...5 22 August 2003 Access Navigator Release 1 8 Physical Installation Attach Access Navigator to Plywood ...
Страница 170: ...6 66 August 2003 Access Navigator Release 1 8 Electrical Installation Exit Management Session ...
Страница 182: ...7 12 August 2003 Access Navigator Release 1 8 Start Management Session NetworkValet EMS and Valet Management ...
Страница 214: ...9 20 August 2003 Access Navigator Release 1 8 Provision DCS Service Test DS1 and DS0 Circuits ...
Страница 296: ...12 18 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via FDL Test DS1 and DS0 Circuits ...
Страница 320: ...13 24 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via IP DS0 Test DS1 and DS0 Circuits ...
Страница 342: ...14 22 August 2003 Access Navigator Release 1 8 Alarm Clearing Ethernet Link Status LED ...
Страница 434: ...16 36 August 2003 Access Navigator Release 1 8 Maintenance Procedures Install SIMM on Controller Card ...
Страница 456: ...17 22 August 2003 Access Navigator Release 1 8 Update Controller Card Software Download Software ...
Страница 634: ...18 178 August 2003 Access Navigator Release 1 8 CLI Language Reference CLI Command List ...
Страница 658: ...B 6 August 2003 Access Navigator Release 1 8 FDL Interface Access Bank II Capabilities ...
Страница 668: ...C 10 August 2003 Access Navigator Release 1 8 SNMP Interface SNMP Trap Reports ...
Страница 682: ...GlossaryGlossaryGlossaryGlossary 14 August 2003 Access Navigator Release 1 8 Glossary ...
Страница 704: ...Index 1 22 August 2003 Access Navigator Release 1 8 Index ...