Alarm Clearing
Active/Standby Controller Status LEDs
Active/Standby Controller Status LEDs
The Access Navigator may have one or two Controller cards, installed in the slots marked Controller A
and Controller B. At least one Controller card is required. If there is only one Controller card, by default
it will be the “active” card.
The Access Navigator can also be equipped as redundant, with two Controller cards. Either Controller
card can be made active during setup. The other Controller card remains in a standby state, ready to take
over in the event that the active Controller fails or is taken out of service. Both Controller cards keep
identical data bases, so that either card can take over and maintain all existing call connections.
NOTE:
One Controller card must always be active, indicated by a green Active status
LED. If there are two Controller cards (protected system), one Controller will be active
(Active status LED lights green) and one Controller will be in standby (Active status LED
will be off).
Table 14-10. Active/Standby Controller Status LEDs
LED State
Description
Troubleshooting
Off
Controller card is in standby.
LED will be off if Controller card is in
standby or is not operational. Use the
status equipment
command for
additional information.
Green
Controller card is active.
Caution
: Do not remove or replace an
active Controller card if there are calls in
progress. In an unprotected system (one
Controller card), the system must be
taken offline for service. In a redundant
system, use the
switch controller
command to put the Controller card in
standby before removing.
Содержание Access Navigator
Страница 1: ...Access Navigator USER MANUAL Part Number 770 0079 AP Product Release 1 8 August 2003 ...
Страница 82: ...4 18 August 2003 Access Navigator Release 1 8 Access Navigator GR 303 Host with P Phone Ordering Information ...
Страница 104: ...5 22 August 2003 Access Navigator Release 1 8 Physical Installation Attach Access Navigator to Plywood ...
Страница 170: ...6 66 August 2003 Access Navigator Release 1 8 Electrical Installation Exit Management Session ...
Страница 182: ...7 12 August 2003 Access Navigator Release 1 8 Start Management Session NetworkValet EMS and Valet Management ...
Страница 214: ...9 20 August 2003 Access Navigator Release 1 8 Provision DCS Service Test DS1 and DS0 Circuits ...
Страница 296: ...12 18 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via FDL Test DS1 and DS0 Circuits ...
Страница 320: ...13 24 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via IP DS0 Test DS1 and DS0 Circuits ...
Страница 342: ...14 22 August 2003 Access Navigator Release 1 8 Alarm Clearing Ethernet Link Status LED ...
Страница 434: ...16 36 August 2003 Access Navigator Release 1 8 Maintenance Procedures Install SIMM on Controller Card ...
Страница 456: ...17 22 August 2003 Access Navigator Release 1 8 Update Controller Card Software Download Software ...
Страница 634: ...18 178 August 2003 Access Navigator Release 1 8 CLI Language Reference CLI Command List ...
Страница 658: ...B 6 August 2003 Access Navigator Release 1 8 FDL Interface Access Bank II Capabilities ...
Страница 668: ...C 10 August 2003 Access Navigator Release 1 8 SNMP Interface SNMP Trap Reports ...
Страница 682: ...GlossaryGlossaryGlossaryGlossary 14 August 2003 Access Navigator Release 1 8 Glossary ...
Страница 704: ...Index 1 22 August 2003 Access Navigator Release 1 8 Index ...