6-60
August 2003
Access Navigator - Release 1.8
Electrical Installation
Verify Operation
5. Verify the following front panel status indications (see Figure 6-40).
Requirement:
DS1
status indicators will blink yellow for 10 to 15 seconds and then light
green when frame synchronization is established. (Indicators will not light
if DS1s are set out of service.)
NOTE:
If status indications are not correct, refer to
Diagnostics & Troubleshooting
on
page 15-1
.
Figure 6-40. Location of DS1 Status Indicators
6. Display status of DS1s on Quad T1 Framer card by entering the following command:
status ds1
<n>
A message similar to the following will appear for each DS1.
Status for DS1 1:
Receive: Traffic
Transmit: Traffic
Requirement:
DS1 status display shows Traffic in receive and transmit directions.
7. Remove DS1 loop back at patch panel.
8. If required, set DS1s on Quad T1 Framer card out of service by entering the following command,
where <n> is the DS1 number or range of DS1 numbers:
set ds1
<n>
down
Example:
set ds1 9 down
Example:
set ds1 9-12 down
9. End management session by entering following command:
exit
1-4
5-8
9-12
13-16
17-20
21-24
26-28
29-32
Содержание Access Navigator
Страница 1: ...Access Navigator USER MANUAL Part Number 770 0079 AP Product Release 1 8 August 2003 ...
Страница 82: ...4 18 August 2003 Access Navigator Release 1 8 Access Navigator GR 303 Host with P Phone Ordering Information ...
Страница 104: ...5 22 August 2003 Access Navigator Release 1 8 Physical Installation Attach Access Navigator to Plywood ...
Страница 170: ...6 66 August 2003 Access Navigator Release 1 8 Electrical Installation Exit Management Session ...
Страница 182: ...7 12 August 2003 Access Navigator Release 1 8 Start Management Session NetworkValet EMS and Valet Management ...
Страница 214: ...9 20 August 2003 Access Navigator Release 1 8 Provision DCS Service Test DS1 and DS0 Circuits ...
Страница 296: ...12 18 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via FDL Test DS1 and DS0 Circuits ...
Страница 320: ...13 24 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via IP DS0 Test DS1 and DS0 Circuits ...
Страница 342: ...14 22 August 2003 Access Navigator Release 1 8 Alarm Clearing Ethernet Link Status LED ...
Страница 434: ...16 36 August 2003 Access Navigator Release 1 8 Maintenance Procedures Install SIMM on Controller Card ...
Страница 456: ...17 22 August 2003 Access Navigator Release 1 8 Update Controller Card Software Download Software ...
Страница 634: ...18 178 August 2003 Access Navigator Release 1 8 CLI Language Reference CLI Command List ...
Страница 658: ...B 6 August 2003 Access Navigator Release 1 8 FDL Interface Access Bank II Capabilities ...