18-88
August 2003
Access Navigator - Release 1.8
CLI Language Reference
CLI Command List
Send Remote T1Drop Line Loopup
NOTE:
This command applies only to a remote Access Bank II connected
to the Access Navigator by a DS1 using Carrier Access FDL management
protocol. For normal operation, the loopback must be disabled by the
send
remote
loopdown
command.
NOTE:
Only one port of the Access Bank II can be looped up at a time. If a
loopup command is received for a second port, the first port will be looped down
automatically before the second port is looped up.
NOTE:
To check remote loopback status, use the
read
remote
loopback
command. See
Read Remote Loopback
on
page 18-51
.
Purpose:
Sends an
out-of-band
(FDL) message to a remote Access Bank II over the Access
Navigator DS1. It is used to verify T1 Drop signal processing.
When the operator enters a
send
remote
command, the Access Navigator transmits
a message over the Carrier Access FDL management channel of the drop DS1. The
Access Navigator’s drop DS1 is the Access Bank’s T1 connection.
The
send
remote
t1drop
line
loopup
command should cause the remote
Access Bank II to perform a line loopback on the T1 Drop output. This takes the
received T1 Drop DS1 signal, loops it in the framer, and sends it back to the T1 Drop
output (see Figure 18-18). To loopdown the interface, use the
send remote loopdown
command.
Figure 18-18. Remote T1drop Line Loopup
Security:
Level 2 (operator)
Syntax:
send remote <n> t1drop line loopup
Example:
send remote 9 t1drop line loopup
Field
Description
n
DS1 number, 1 to 32
DS1
Access
Navigator
Framer
CA FDL
Command
Access Bank II
T1 Drop
Line Loopup
T1
Framer
T1 Drop
DS1
Time Slot
Interchange
Содержание Access Navigator
Страница 1: ...Access Navigator USER MANUAL Part Number 770 0079 AP Product Release 1 8 August 2003 ...
Страница 82: ...4 18 August 2003 Access Navigator Release 1 8 Access Navigator GR 303 Host with P Phone Ordering Information ...
Страница 104: ...5 22 August 2003 Access Navigator Release 1 8 Physical Installation Attach Access Navigator to Plywood ...
Страница 170: ...6 66 August 2003 Access Navigator Release 1 8 Electrical Installation Exit Management Session ...
Страница 182: ...7 12 August 2003 Access Navigator Release 1 8 Start Management Session NetworkValet EMS and Valet Management ...
Страница 214: ...9 20 August 2003 Access Navigator Release 1 8 Provision DCS Service Test DS1 and DS0 Circuits ...
Страница 296: ...12 18 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via FDL Test DS1 and DS0 Circuits ...
Страница 320: ...13 24 August 2003 Access Navigator Release 1 8 Provision Remote Adit 600 via IP DS0 Test DS1 and DS0 Circuits ...
Страница 342: ...14 22 August 2003 Access Navigator Release 1 8 Alarm Clearing Ethernet Link Status LED ...
Страница 434: ...16 36 August 2003 Access Navigator Release 1 8 Maintenance Procedures Install SIMM on Controller Card ...
Страница 456: ...17 22 August 2003 Access Navigator Release 1 8 Update Controller Card Software Download Software ...
Страница 634: ...18 178 August 2003 Access Navigator Release 1 8 CLI Language Reference CLI Command List ...
Страница 658: ...B 6 August 2003 Access Navigator Release 1 8 FDL Interface Access Bank II Capabilities ...
Страница 668: ...C 10 August 2003 Access Navigator Release 1 8 SNMP Interface SNMP Trap Reports ...
Страница 682: ...GlossaryGlossaryGlossaryGlossary 14 August 2003 Access Navigator Release 1 8 Glossary ...
Страница 704: ...Index 1 22 August 2003 Access Navigator Release 1 8 Index ...